Download Print this page

Honeywell PX2 Series Installation Instructions Manual page 5

Heavy duty transducers

Advertisement

PX2 Series Heavy Duty Pressure Transducers
Figure 3. Electrical Connector Type Dimensions (For reference only: mm/[in].)
A
Delphi Metri-Pack 150, Standard
(UL 94 HB)
J
Delphi Metri-Pack 150
(UL 94 V-0)
Connector: DELPHI 12078088
Mating Connector: DELPHI 12110192
IP Rating
: IP65 (all versions)
1
Voltage
Pin
Output
A
GND
B
V+
C
Vout
IP rating is determined by the electrical connector type chosen.
1
Connector: IEC 61076-2-101
Mating Connector: 4 POS TYPE D
IP Rating
: IP65/IP67 (absolute, sealed gage
1
versions)
IP65 (vented gage versions)
Current
Pin
Output
RTN
1
supply
3
NC
4
Hole
(vented gage
versions only)
B
Micro M12
(IEC 61076-2)
Voltage
Current
Output
Output
V+
supply
GND
RTN
Vout
NC
Hole
(vented gage
versions only)
50052336
C
DIN
(EN 175301-803C)
Connector: EN 175301-803C
Mating Connector: EN 175301-803C DIN
43650C 8MM
IP Rating
: IP65 (all versions)
1
Voltage
Pin
Output
1
GND
2
V+
3
Vout
PE
NC
Honeywell Sensing and Control
ISSUE 8
Current
Output
RTN
supply
NC
NC
Hole
(vented gage
versions only)
5

Advertisement