Salcom 12-84-7000 Product Manual

Vhf/uhf relay output receiver

Advertisement

Quick Links

12-84-7000
VHF / UHF Relay Output Receiver
PRODUCT MANUAL
Version 1.01
February 2019
Copyright © 2017 Sea Air and Land Communications Ltd. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Salcom 12-84-7000

  • Page 1 12-84-7000 VHF / UHF Relay Output Receiver PRODUCT MANUAL Version 1.01 February 2019 Copyright © 2017 Sea Air and Land Communications Ltd. All rights reserved.
  • Page 2 P a g e Salcom Product Documentation This document is designed to familiarise you with Salcom products and guide you through the hardware, configuration, installation and overall system management. Salcom is an environmentally conscious company and in an effort to conserve paper no longer prints manuals with shipped products.
  • Page 3: Warranty And Disclaimer

    P a g e Warranty and Disclaimer Salcom products are warranted for a period of 12 months from the date of purchase against faulty materials and workmanship. Should any fault occur the unit should be returned to the vendor, freight pre-paid. Please include a description of the fault to assist with prompt return. Any unauthorised alterations or repairs will invalidate the warranty.
  • Page 4: Product Overview

    P a g e Product Overview The 12-84-7000 Relay Output Receiver is available in two versions, a VHF 12-84-7150 and a UHF 12-84- 7450 both of which provide four outputs (2 relay and 2 open collector) which can be controlled remotely via SALCOM transmitters or wide area paging networks.
  • Page 5: Installation And Connections

    Relays are not to be connected directly to mains voltages. Open collector outputs are best suited to drive external relays, as indicators or to drive inputs that have moderate to low current requirements. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 6 RS232 Out Relay 2 Common RS232 In Relay 1 Normally Open Relay 1 Normally Closed Relay 1 Common 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand February 2019...
  • Page 7: Operation

    Each output can have its own mono-shot time, ranging from 25mS to 30 minutes in 25mS steps. Setting the value to 0 disables the mono-shot timer altogether, and the output is latched until commanded off. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 8 P a g e Commands The outputs of the 12-84-7000 are controlled by a series of numeric commands sent in the form of a numeric or alphanumeric pager message. Note: Control strings can be sent as numeric or alpha-numeric messages. Numeric messages are shorter, and are therefore more efficient to transmit.
  • Page 9 To turn on outputs 1,2 and 4 4412409 To turn output 1 on and output 3 off 441039 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand February 2019...
  • Page 10 Preparing to Use the Programming Software To change the field programmable options, the unit must be connected to a PC using Windows XP or later, running the 12-8 PSD programming software, downloadable from Salcom’s website http://www.salcom.com/media/software/Salcom-12-84SE-PSD-v1014.zip Connection should be from the serial port S2 on the 12-84 to a com port on the PC.
  • Page 11 Next select ‘Connect’. The status at the bottom of the 12-84 PSD will indicate if successfully connected, see below: 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 12 Reprogram the unit by clicking the Program button to upload the changes to the 12-84. After programming the PSD will provide feedback if the user selected operations are successful. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 13 Default Freq: When using Vehicle Id, up to 3 frequencies can be pre-defined using the programming tool for use with this feature. Valid settings are ”1”, “2” and ”3”. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 14 Valid RIC values are between 8 and 2000000. Decode: The expected format for the message to be decoded from. Available options are ‘Alpha Numeric” or “Numeric”. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 15 Minimum busy level to be exceeded -125dBm Maximum busy level to be exceeded -80dBm Default busy level to be exceeded 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand February 2019...
  • Page 16 This should not be used for general relay control, using the relay control protocol is the preferred method. 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 17: Serial Data Output

    If the need arises to monitor paging messages on a network, the 12-84 can provide serial data output (9600 Baud N:8:1) via the programming connector. The 12-84 can be connected to the serial port of a PC using a Salcom 12-45 programming lead. The format of the carriage return terminated output string is as follows: 5 12.A.S.0.1234567 TXT...
  • Page 18: Technical Specification

    P a g e | 17 Technical Specification Technical Specification 12-84-7000 – VHF / UHF Relay Output Receiver Frequency Range 148-165MHz - VHF (Model No. 12-84-7150) 440-480MHz - UHF (Model No. 12-84-7450) Frequency Selection User configurable Note: VHF model is only adjustable by 5MHz from (customer defined) ±...
  • Page 19: How To Contact Us

    P a g e | 18 How to Contact Us Sea Air and Land Communications (Salcom) Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand +64 (0)3 379 2298 W: www.salcom.com support@salcom.com sales@salcom.com 12-84-7000 RELAY OUTPUT RECEIVER Product Manual Sea Air and Land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...

Table of Contents