  • Page 1 12-88-7000 Output Control Receiver PRODUCT MANUAL Version 1.02 July 2017 Copyright © 2017 Sea Air and Land Communications Ltd. All rights reserved.
  • Page 2 P a g e Salcom Product Documentation This document is designed to familiarise you with Salcom products and guide you through the hardware, configuration, installation and overall system management. Salcom is an environmentally conscious company and in an effort to conserve paper no longer prints manuals with shipped products.
  • Page 3: Warranty And Disclaimer

    P a g e Warranty and Disclaimer Salcom products are warranted for a period of 12 months from the date of purchase against faulty materials and workmanship. Should any fault occur the unit should be returned to the vendor, freight pre-paid. Please include a description of the fault to assist with prompt return.
  • Page 4: Product Overview

    P a g e Product Overview The 12-88-7000 is a high sensitivity VHF/UHF paging receiver which is able to control 3 outputs (one relay and two as open collector). It operates over the two frequency ranges, VHF 148Mhz to 165MHz (model 12-88-7150) and UHF 440Mhz to 470MHz (model 12-88-7450). The 12-88-7000 decodes 512 or 1200 baud, alphanumeric or numeric Salcom control protocol messages.
  • Page 5: Installation And Connections

    Pin numbering: looking into the sockets, pin 1 is on the left. Description +12V Output 3 Output 2 Do not connect Relay Normally Open Relay Common Relay Normally Closed 12-88-7000 OUTPUT CONTROL RECEIVER Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand July 2017...
  • Page 6: Operation

    To control the outputs a message must be received that matches the unit ID with a suitable control code sequence (Salcom relay control protocol). The received message must also be the expected baud rate (512 or 1200) and format (alphanumeric or numeric). The 12-88 will also respond to a group unit ID of “00”.
  • Page 7: Output Control

    P a g e Output Control Outputs are controlled using Salcom relay control protocol. The control message must be at the start of the paging message in order to be processed. Outputs 2 and 3 are treated as relays in the examples below for clarity.
  • Page 8 P a g e Configuration In order to program the12-88-7000, programming software should be downloaded from the Salcom website (www.salcom.com). Alternatively, a suitable terminal program can be used to program the 12-88-7000. To connect the programming computer to the 12-88-7000 either use a •...
  • Page 9: Configuration Commands

    A1200, N512 or N1200. ‘A’ specifies alphanumeric operation. ‘N’ specifies numeric operation. 512 and 1200 specifies the receiver decode baud rate. Typical usage: +03=A512<CR> 12-88-7000 OUTPUT CONTROL RECEIVER Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand July 2017...
  • Page 10 O/P Restore: If set to 1, then all outputs that are not configured for monoshot operation will be saved so that when the power is cycled the output will return to that state. 12-88-7000 OUTPUT CONTROL RECEIVER Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 11: Technical Specification

    -10 to +50degC Enclosure Dimensions: 66mm x 50mm x 26mm (with mounting holes). Material: Plastic Environmental Protection Indoor use only 12-88-7000 OUTPUT CONTROL RECEIVER Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand July 2017...
  • Page 12: How To Contact Us

    P a g e | 11 How to Contact Us Sea Air and Land Communications (Salcom) Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand +64 (0)3 379 2298 W: www.salcom.com support@salcom.com 12-88-7000 OUTPUT CONTROL RECEIVER Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...