Issue A 06/02 12-04-0000 POCSAG Relay Output Receiver GENERAL The 12-04-0000 POCSAG Relay Output Receiver provides the ability to remote control relay outputs using SALCOM paging systems or telephone wide area paging networks. OPERATION The unit receives and decodes a numeric or alphanumeric pager call.
SALCOM 12-04-0000 POCSAG RECEIVER with RELAY OUTPUTS Issue A 06/02 UNIT NUMBER Each unit will respond only to messages which contain a matching Unit Number . Up to 99 unique unit numbers are available. Any number of units can be programmed with the same unit number.
Page 6
SALCOM 12-04-0000 POCSAG RECEIVER with RELAY OUTPUTS Issue A 06/02 COMMANDS The OUTPUT Relay of the 12-04-0000 is controlled by a series of numeric commands sent in the form of a numeric or alphanumeric pager message. Note: For best sensitivity and range, it is better to send the command as a numeric paging message, as this uses the least number of characters.
OPTIONS Some options are available for the 12-04 to extend its use to other situations. All these options can only be fitted by the SALCOM factory and must be requested at the initial order. A 10A 240VAC relay can be fitted to allow the unit to switch mains operated equipment.
Page 8
SALCOM 12-04-0000 POCSAG RECEIVER with RELAY OUTPUTS Issue A 06/02 Sea Air and Land Communications Ltd Page 8...