45° in each direction from centre, and tilted in a range of 45°
while suspended from a wall or ceiling.
!
NOTE: The hardware for mounting the hanger bracket to the
wall or ceiling is not included.
CAUTION: When turning and/or tilting the heater do not
block the exhaust opening.
Figure 3
Hanger
T-Handle
Bracket
Lock
Washer
Spacer
Carriage
Bolt
Air In
Operation
WARNING: This heater must be properly installed before it is
used.
SETTING THE THERMOSTAT
1. Before connecting or disconnecting plug, turn knob fully
counterclockwise. (Figure 4)
2. Heater is equipped with a thermostat. To adjust temperature
to your individual requirements, turn thermostat control knob
clockwise all the way to turn heater on. The yellow power light
will illuminate. When room reaches desired temperature, turn
thermostat knob counterclockwise until you hear click. Leave
in this position to maintain room temperature at this setting.
For additional heat, turn clockwise until you hear click again
and heater will turn on. To shut heater off turn thermostat knob
counterclockwise all the way. The yellow power indicator light
will turn off.
!
NOTE: Heater is equipped with a fan delay to dissipate
residual heat from the element. Heater fan will run for a brief
period after heater has reached room temperature.
WARNING: Should the heater overheat, an automatic cut out
will turn the heater off and it will not come back on without
being reset. It can be reset by unplugging the unit and waiting
5 minutes before plugging the unit back in.
If you need to continuously reset the heater, unplug the
unit and contact a licenced electrician. DO NOT USE THE
HEATER UNTIL THE CAUSE OF THE PROBLEM IS
DETERMINED AND FIXED.
1367 Industrial Road Cambridge ON Canada N3H 4W3
1-888-346-7539 www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2017 Dimplex North America Limited
1. Locate a stud or other suitable
support and install hanger
bracket on wall or ceiling.
Select a location where the
control knob can be easily
reached.
2. Insert carriage bolt into square
opening of heater handle.
3. Slide spacer over the carriage
bolt shaft and insert in hanger
bracket opening and hold them
in position.
4. Slide lock washer and thread
on T-Handle onto carriage bolt,
turning to tighten.
Air Out
Figure 4
O
Low
High
Yellow light
Power On
En marche
Encedido
Over Temp
Surchauffe
Temperatura
Red light
Excesiva
Maintenance
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of fire, electric shock
or damage to persons.
CAUTION: Allow at least 30 minutes for the heater to cool
before attempting any maintenance or cleaning.
!
NOTE: This heater should not be operated with an
accumulation of dust or dirt on or in the unit, as this can cause
a build up of heat and eventual damage. For this reason the
heater must be inspected regularly, depending upon conditions
and at least at yearly intervals.
To clean the exterior surface, use a solution of water and mild
detergent, apply with damp sponge. Wipe dry with a dry cloth.
DO NOT plug heater into outlet until it has dried thoroughly.
Warranty
Dimplex Electric Heaters are tested and inspected prior to shipment and are
guaranteed free from defect to the purchaser of each new product. Any part
which proves to be defective in material or workmanship under normal use
within one year will be repaired or replaced without charge. The Company
will not be responsible for any expense incurred for installation, removal from
service, or transportation costs. Any such defect should be brought to the
attention of the Dealer where the product was purchased and is authorized to
repair or replace within the terms of this warranty.
The Company's only obligation under this warranty will be at its sole option
to repair or replace any part proving defective or to refund the purchase price
thereof.
The owner/user assumes all other risks, if any, including the risk of any direct,
indirect or consequential loss or damage arising out of the use of or inability
to use the product.
The warranty will not apply if, in the sole judgment of the Company, damage
or failure has resulted from accident, alteration, misuse, abuse, incorrect
installation, or operation on an incorrect power source.
The foregoing is in lieu of all other warranties expressed, implied, or statutory,
and the Company neither assumes, nor authorizes any person to assume for
it any other obligation, or liability in connection with said product.