TRIANGULATION LASER SENSORS, RF603 Series
1. GENERAL INFORMATION
The sensors are intended for non-contact measuring and checking of position, displacement,
dimensions, surface profile, deformation, vibrations, sorting and sensing of technological objects as
well as for measuring levels of liquid and bulk materials.
The series includes 24 sensors with the measurement range, from 2 to 1000 mm and the base
distance from 10 to 245 mm. Custom-ordered configurations are possible with parameters different
from those shown below.
2. BASIC TECHNICAL DATA AND PERFORMANCE CHARACTERISTICS
RF603-
Base distance, X, mm
Working range, mm
Linearity, %
Resolution, %
Maximum sampling rate
Laser type
digital
Output signal
analog
Synchronization input
Power Supply, V
Alarm output
Power consumption, W
Enclosure rating
Operating temperature, °С
Weight (without cable), g
RF603-R-39/4 sensor is designed to use with mirror surfaces and glass
Note #1:
All specifications for the rest sensors apply for a diffusely reflecting white paper
Note #2:
CE compliance.
The sensors are designed for use in industry and are in compliance with the following standards:
-
EN55022:2006 Information technology equipment. Radio disturbance characteristics. Limits
and methods of measurement:
-
EN61000-6-2:2005 Electromagnetic compatibility (EMC). Generic standards. Immunity for in-
dustrial environments
-
EN61326-1:2006 Electrical equipment for measurement, control and laboratory use. EMC re-
quirements. General requirements
The sensors fulfil the specification of the EMC requirements, if the instructions in the manual are
followed.
Page 1/25
Rev. F (14.09.2009)
RIFTEK, Republic of Belarus
R-X/4 X/2 X/5
X/10
15, 25
39
10
15
60
4
2
5
10
±0,2
1mW
1...3 mW, wavelength 660 nm
RS232 (460,8 kbit/s max) or RS485 (921,6 kbit/s max) or RS232 and CAN V2.0B
5 (4,5...9) or 12 (9...18) or 24 (18...36)
-10...+60, (-30...+60 for the sensor with built-in heater),
(-30...+120 for the sensors with cooling housing)
, Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com
X/15
X/25
X/30
X/50
15, 30
25, 45
35, 55
45, 65
65
80
95
105
15
25
30
50
±0,1of the range
0.03 of the range
2 or 5 or 8
kHz
(1 Mbit/s) or CANopen and RS232
4...20 mА (≤500 Ω load) or 0...10 V
2,4-5 V (CMOS, TTL)
NPN: 100 mA max; 40 V max
1,5...2
IP67
100
X/100 X/250 X/500 X/750 X/1000
60, 90
80
125
145
140
100
250
500
750
±0,2...0,3
5mW, 660 nm
245
1000
0,05

Advertisement

loading
Need help?

Need help?

Do you have a question about the RF603 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Riftek RF603 Series

  • Page 1 EN61326-1:2006 Electrical equipment for measurement, control and laboratory use. EMC re- quirements. General requirements The sensors fulfil the specification of the EMC requirements, if the instructions in the manual are followed. Page 1/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 2 Figure 3. Sensor package is made of anodized aluminum. The front panel of the package has two windows: one is output, the other for receiving radiation reflected from the object under control. The package also contains mounting holes. Page 2/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 3 Requirements for its 5.3. mounting are shown in Figure 4a. The special mounting device is included into the shipping (Fig 4b). Figure 4a Figure 4b Page 3/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 4 Power U- Brown DATA+ Green DATA- Yellow Blue White/Violet Pink/Orange Gnd (Common for signals) Grey/Black 7. INPUT-OUTPUT SCHEMATIC 7.1. Synchronization input 7.2. Alarm Page 4/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 5 On hardware level, sensor synchroni- zation is carried out by combining AL lines. Page 5/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 6 9.3. Network data communications protocol assumes the presence of ‘master’ in the net, which can be a computer or other information-gathering device, and from 1 to 127 ‘slaves’ (RF603 Series sensors) which support the protocol. Each ‘slave’ is assigned a unique network identification code –...
  • Page 7 — Inquiring of result — - result Inquiring of a stream of results — - stream of results Stop data streaming — — Page 7/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 8 0…7FFh,(by default — 7FFh) specifies standard CAN identifier High byte of standard identifier 0th byte of extended identifier 0…1FFFFFFFh, (by default — 1FFFFFFFh) specifies extended CAN Page 8/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 9 Inquiry (‘master’) — 01h, 86h; Answer (‘slave’) — B5h, BAh, B2h, B0h The displacement (mm) is equal (for example, range of the sensor = 50 mm): Page 9/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 10 11.1. The sensor with CANopen interface has two connectors, Fig. 5. Connector Symbols D-sub 9-pin (fem) Wire color 1. 232-U-IN-AL Power U+ Power U- Brown Green Yellow Blue White/Violet Pink/Orange Page 10/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 11 Number of elements Number of elements UI32 180h+Node-ID COB-ID PDO used COB-ID Asynchronous regime Transmission Type (see 02h parameter in the table of parameters) Page 11/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 12: Setup Program

    1. In the line “UART Baud rate” select sensor operation speed (factory setting – 9600 bit/s), 2. In the line “COM number” select PC RS232 port number where sensor is connected. Page 12/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 13 Sampling Period parameter. The 07h request type is realized in this case (see par. 8.9). 4) By moving the object within the operating range, observe changes of readings on the display and oscilloscope. Page 13/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 14 1% of the working range. Call out the control toolbar by clicking twice in the ‘Value’ field: Page 14/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 15 5) To save sensor parameters on the disk, select "Write to file". 6) To read sensor parameters from the disk, select "Read from file". Page 15/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 16 TRIANGULATION LASER SENSORS, RF603 Series 13. RF60X-SDK. FUNCTIONS DESCRIPTION Laser sensor is supplied together with SDK (www.riftek.com/resource/files/rf60x-sdk_eng.zip) consisting of: - dynamic library RF60x.dll, - file for static linking of DLL to project RF60x.lib, - definition file RF60x.h. The SDK allows user to develop his own software products without going into details of the sensor communications protocol.
  • Page 17 – RF60x_OpenPort, or CreateFile; address of the device; bAddress number of parameter, see Table 1, wParameter Page 17/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 18 FALSE, otherwise, if record confirm is obtained from the sensor, the function returns TRUE. 13.6. Restoration of default parameters from FLASH-memory (RF60x_RestoreFromFlash). The function RF60x_RestoreFromFlash restores all parameter values in the FLASH by default: Page 18/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 19 If the device does not respond to result request, the function returns FALSE, otherwise, if the re- store confirm is obtained from the sensor, the function returns TRUE. Page 19/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 20 RF603 sensor parameters. The parameter is identical to the parameter lpusValue lpus- in the RF60x_Measure function. Value BOOL RF60x_GetStreamMeasure( hCOM, HANDLE lpusValue USHORT * Page 20/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 21 13.14. You can find examples of programs for LabView here: www.riftek.com/resource/files/rf60x_labview_example.zip 13.15. You can find examples of programs for Visal Basic 6 here: www.riftek.com/resource/files/rf60x-vb.zip Page 21/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 22 //Obtain distance values from RF603 sensor RF60x_Measure( hRF60x, 1, &usMeasured ); /* usMeasured contains measurement result */ RF60x_ClosePort( hRF60x ); Page 22/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 23 EXAMPLE 3 (how to get a result with latching) for (int i=0;i<100;i++) // Result latching RF60x_LockResult(hRF60x, 1); // Result receiving RF60x_Measure( hRF60x, 1, &usMeasured); printf("Measure-l \t: %d\r\n", usMeasured); Page 23/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 24 C for air pressure of 6 atm. 4) The sensor is calibrated directly in the housing, therefore if the device is used without housing linearity of characteristics is lost. Page 24/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...
  • Page 25: Warranty Policy

    Tel/fax.: +38 057 714 26 54 Tiffield road, Towcester, Northents, Fax. 93 334 05 24 http://www.koda.com.ua myct@iberfluid.com mail@koda.com.ua Tel.: 01327 353437 http://www.iberfluid.com Fax: 01327 353564 www.ixthus.co.uk info@ixthus.co.uk Page 25/25 Rev. F (14.09.2009) RIFTEK, Republic of Belarus , Minsk, tel./fax: +375-17-281-35-13 Е-mail: info@riftek.com, http:// www.riftek.com...