Carlin 51300AS Installation Instructions & Operating Manual

Cap system kit combustion air proving kit with burner cut-off

Advertisement

Quick Links

3
2
1
6
5
4
Cover Seal Kit (not shown) – 50433KITS
8
Air Pressure Switch Wiring Harness (not shown)
9
3" Pipe Elbow w/ Birdscreen (not shown)
CAP
Description
Model
Low Rate CAP Kit
51300AS
(for Carlin burners with covers)
Medium Rate CAP Kit
51300BS
(for Carlin burners with covers)
High Rate CAP Kit
51300CS
(for Carlin burners with covers)
Complete
51300S
CAP System Kit
(for Carlin burners without covers)
Note: All CAP System models require 7 Carlin 70200 Primary Control manufactured after Sept. 2018
©
Copyright 2018 – Carlin Combustion Technology, Inc.
7
Firing Rate (GPH)
1 Air Pressure Switch Assembly with 50806A Switch, 2 Combustion Air Inlet,
0.50 - 1.00
3 Connecting Flange, 4 Cover Seal Kit, 8 Air Pressure Switch Wiring Harness,
9 3" Pipe Elbow w/ Birdscreen
1 Air Pressure Switch Assembly with 50806B Switch, 2 Combustion Air Inlet,
1.05 - 1.45
3 Connecting Flange, 4 Cover Seal Kit, 8 Air Pressure Switch Wiring Harness,
9 3" Pipe Elbow w/ Birdscreen
1 Air Pressure Switch Assembly with 50806C Switch, 2 Combustion Air Inlet,
1.50 - 2.00
3 Connecting Flange, 4 Cover Seal Kit, 8 Air Pressure Switch Wiring Harness,
9 3" Pipe Elbow w/ Birdscreen
1 Air Pressure Switch Assembly with 50806A, B & C Switches, 2 Combustion Air Inlet,
0.50 - 2.00
3 Connecting Flange, 4 Cover Seal Kit, 5 Cover, 6 Cover Back Plate,
8 Air Pressure Switch Wiring Harness, 9 3" Pipe Elbow w/ Birdscreen
System Kit
Air Proving Kit with
Burner Cut-Off
Designed to meet NFPA31*
requirements for combustion air
Installation Instructions
and Operating Manual
*See Section 5.4.3.3 as covered by April 2019 TIA 16-2
Contains
Carlin Combustion Technology, Inc.
126 Bailey Road
Phone 203-680-9401
T
800-989-2275
ech support
CAP
Combustion
North Haven, CT 06473
Fax 203-680-9403
carlincombustion.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 51300AS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carlin 51300AS

  • Page 1 CAP System Kit 8 Air Pressure Switch Wiring Harness, 9 3" Pipe Elbow w/ Birdscreen (for Carlin burners without covers) Note: All CAP System models require 7 Carlin 70200 Primary Control manufactured after Sept. 2018 Carlin Combustion Technology, Inc. 126 Bailey Road...
  • Page 2 50806C bottom corners of the filler plate to properly align the filler plate with the burner back plate. Ensure that the burner is equipped with a Carlin Pro-X 70200 primary control with low voltage blocked vent (BV) terminals as shown.
  • Page 3 Vent Input has been “Entered” and has replaced any previous setting. NOTE: If the Pro-X 70200 is also connected to a blocked exhaust switch, call Carlin Technical Support for assistance. INSTALL THE AIR INLET • Using the screws provided, install the CAP System air Install 3"...
  • Page 4 The air pressure switch must correspond with the firing rate With the CAP System installed and the cover securely of the burner – see table on page 2. Carlin’s Complete CAP mounted, initiate a call for heat and allow the burner to System Kit (51300S) contains all three pressure switches.

This manual is also suitable for:

51300bs51300s51300cs

Table of Contents