Congratulations on your purchase of the thermal imaging camera IR-CAM4 meet the requirements of service organizations, construction companies, service CONDTROL. providers. IR-CAM 3 CONDTROL combines professional features, intuitive Safety instructions provided in this user manual should be carefully read before operation and a wide range of measured temperatures.
3) Others gain and brightness Date/time, temperature unit, Iron and steel industry: Inspect steel refining and rolling processes; diagnose Setup functions language hot-blast stove defects; detect the embryo temperature of armor plate, etc. Emissivity correction Variable from 0.01 to 1.0 Firefighting: Forest fire prevention and detection of latent ignition source.
4. DELIVERY PACKAGE Thermal imager Carry case Li-ion battery (2 pcs.) User manual CD-disk Battery charger Lens cap Memory card Memory card reader 10. USB cable 5. PRODUCT DECRIPTION 5.1. Buttons 1 - Power key Press and hold the Power Key for > 3 seconds to power on/off the camera. Note: After powering off, please wait ten seconds before powering the camera on again.
Page 5
Pressing the Menu key will pop up the attribute box. In this box, the user can image. Press Confirm to save the image or Press C to return to real-time select to adjust either position or size of the area. After selection, the arrows will measurement.
5.2. Interface 5.3. Display 1 - Operating status: displays the current operational status. 1 - USB output 2 - Spot temperature measurement: White crosshair. Inserting USB cable to this port and connecting to computer for data 3 - Selected spot temperature: Yellow crosshair, and show by“*” . transmission (only support USB2.0).
NOTE: Not all models have all functions, so the working status screen may not Replace the cover and screw down. show all features. 6. BEFORE START OPERATION 6.1. Battery installation and replacement Battery compartment is located inside the handle. Turn the cover counter-clockwise to remove.
6.4. Menu Main menu Powering off display It’s better to replace batteries now. 6.3. Battery safety and usage Batteries should be stored in an ambient temperature of -4°F (–20°C) to 1 - Main menu: Displays four options: Measurement, auto/manually, Setup, and 67.9°F (+20°C).
3 - Item content: Items show specified content. Black means valid or changeable Add Hot Spot – adds a moving cursor that automatically displays the and white means invalid for this selection. 4 - Unit: Indicates the current selected temperature unit. hottest spot in the image.
low-level menu will display the inactive mode followed by a “?”. Pressing the > Press Menu key to activate the main menu. Select Setup->MeasureSet and press key followed by the Confirm key will switch to the displayed mode. Press A key to Confirm key to pop up the Measuring Setup dialog box.
Set Alarm Temp .set as low temp. trigger alarm when lower than temp Customize:Select material from pre-defined list via left and right keys. TCorrect:Temperature correction setup. of Set Alarm Temp Distance: Distance setup Alarm Color: Selects the color in which the alarming pixels are displayed. ...
6.4.3.5. System setup Video Mode: Allows selection of PAL or NTSC video output. Standby Time:Allows user to select None, 2, 5, 10 or 15 minutes. If no button depressions are made during the set time, the camera will turn off the screen automatically, to prolong battery life.
6.4.3.7. Factory Default 6.4.4. File 6.4.4.1. Open Press Menu key to activate the main menu. Select File->Open, press Confirm It is used for resetting factory defaults. Press Menu key to activate the main key to open the saved images. Press Left and Right keys to change the images. menu.
6.4.4.2. Save It is used for saving the image, performs the same functionality as the Save key. Press Menu key to activate the main menu. Select File->Save, press Confirm key to save the current image into the TF card or highlight Cancel and press Confirm key to cancel Save operation.
CAUTION: Before formatting, make sure all files are not needed or already 6.4.4.4. Delete backed up. Data cannot be recovered after formatting. If formatting via PC, please use FAT16 format. Used for deleting the image. When camera is in image replay mode, press Menu key to activate the main menu, select File->Delete, press Confirm key to pop out the below prompt box.
camera, it will display <XXX° or >XXX° with XXX being the min or max temperature of the selected range. 7.3. Freeze and save image To modify the measurements attributes, select the measurement parameter, and then press the Confirm key. The screen will display the Press S key to freeze the image and select “C”...
8. TROUBLESHOOTING 9. CARE AND MAINTENANCE Please follow the table below to diagnose and correct the problem. If problem still exists, please contact our service department. Attention! This product is an accurate optical and electronic device and requires delicate handling. If the device is given to somebody for temporary use, be sure to Problem Cause &...
- Do not leave discharged battery in the device. warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product. 4) Condtrol GmbH reserves the right to decide on replacement or repair of 10. UTILIZATION the device.
Page 19
Timber Dressed 0.90 Appendix A Water Distilled water 0.96 Common material emissivity(FYI) Skin Human 0.98 Material Surface Temperature°C Emissivity ( ε ) Thin 0.90 Ceramic Thick 0.93 Non- oxidized 0.20 Aluminum Oxidized 0.55 Appendix B Burnished to 0.40 Brown Factory default parameter setting table Brass Dull luster 0.22...