Positioning
Step
Target position
1
Place the
first target
2
"A" in
position
3
tuning
completed
Notes : In positioning, you have to push the tuning button only once for teaching.
Do not push the tuning button twice, as in "contrast" setting.
If the level of light reception is too low, "E" will flash. Try moving the fibre closer to the target.
The alarm is locked On (Output Off) until you re-teach the sensor.
Maximum sensitivity
Step
Operation
SET
1
RUN
Switch the operation
mode selector to "SET"
2
Push the tuning button
for 3 seconds
SET
3
RUN
Switch the operation
tuning
mode selector to "RUN"
completed
Off-Delay timer setting
Off-delay timer status
To activate
To de-activate
© Honeywell Europe S.A.
Operation
Digital
SET
RUN
Switch the operation
"1" is indicated
mode selector to "SET"
for step 1
Push the tuning button
"2" is indicated for
once (first teaching)
step 2
SET
RUN
Switch the operation
Level of light recep-
mode selector to "RUN"
tion is displayed
Indicator status
Red LED Green LED
Digital
OFF
"1" is indicated
for step 1
ON
"H" is displayed
Depends
on LO/DO
setting
Level of light recep-
tion is displayed
Operation
Digital display
Push the teach button
for 10 seconds
Off-delay "ON"
Push the teach button
for 10 seconds
Off-delay "OFF"
Indicator status
Red LED Green LED
OFF
OFF
FLASH
OFF
Depends
Should be
on LO/DO
ON
setting
for stable
operation
This setting is equivalent to turning the potentiometer to
its maximum position on a conventional sensor. The
function has been mainly designed for Through-Scan
fibre applications.
Note: Unlike the contrast, positioning a target is not
OFF
necessary for this maximum setting.
ON
Should be
ON
for stable
operation
To activate or to de-activate the Off-Delay timer, make
sure that the operation mode selector is switched to
"RUN". The Off-Delay function latches the output On for
40 milliseconds before switching to Off. This prevents
the sensor from reacting to holes or irregularities in the
target.
Alarms for errors
Insufficient light
Digital Red
Green
LED
LED
FLASH FLASH
FLASH OFF
"E" for
error
will flash