Raypak ELS 0005 Installation And Operation Manual

Raypak ELS 0005 Installation And Operation Manual

Electric 3-series titanium heater

Advertisement

INSTALLATION AND OPERATION
Electric Heater
MODELS
ELS 0005, ELS 0011,
ELS 0018, and ELS 0027
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance.
To do so may result in an explosion or fire.
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced
in the installation and maintenance of this type of equipment and related system components. Installation and
service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.
This manual should be maintained in legible condition and kept adjacent to the electric heater or in a safe place
for future use.
CATALOG NO. 6100.63C
MANUAL
Effective: 05-01-19
Tested to UL Standard 1261
Replaces: 03-01-19
4000856
P/N 241758 Rev 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELS 0005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Raypak ELS 0005

  • Page 1 INSTALLATION AND OPERATION MANUAL Electric Heater MODELS ELS 0005, ELS 0011, ELS 0018, and ELS 0027 4000856 Tested to UL Standard 1261 FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CONTENTS 1. WARNINGS ..............2 8. FREEZE PROTECTION ..........5 2. WATER CHEMISTRY ........... 3 9. ELECTRICAL CONNECTIONS ........5 3. SAFETY INFORMATION ..........3 10. OPERATION ..............6 4. OVERVIEW ..............3 11. CONTROL ..............7 5. BEFORE INSTALLATION ..........4 12.
  • Page 3: Water Chemistry

    If you have any questions, please contact your and salt chlorinators are usually more efficient in heated Authorized Dealer, or visit our website at www.raypak.com. water. If not controlled, they can lead to high chemical levels which can damage the heat exchanger. Further...
  • Page 4: Before Installation

    • Models ELS 0005 and 0011 are supplied with BEFORE INSTALLATION 1-1/2" NPT inlet and outlet plumbing connections. Please read these instructions thoroughly and completely • Models ELS 0018 and 0027 are supplied with before installation and before use. Failure to do so could 2"...
  • Page 5: Freeze Protection

    CHECK VALVE TO SPA/POOL FILTER CHLORINATOR PUMP BYPASS (CUSTOMER INSTALLED) DRAIN VALVE (CUSTOMER INSTALLED) GATE VALVE FROM SPA/POOL F10545 Figure 1. Spa/Pool Installation Diagram As with all electrical appli ances, under no circumstances FREEZE PROTECTION should you attempt to install, repair or disassemble this heater without first shutting off all power to the heater If the heater is installed in a location subject to freezing directly at the fuse or breaker box.
  • Page 6: Operation

    10. OPERATION Once the heater is installed, it can be used year round. Models ELS 0005 and 0011 display the inlet temperatures The user MUST makes sure the pump is not disengaged on the GPM screen by turning the knob to the right. The...
  • Page 7: Control

    PUSH BUTTON ONCE PUSH BUTTON ONCE PRESS SECONDS PRESS SECONDS Figure 3. Digital Control for Models ELS 0005 and 0011 Figure 4. Digital Control for Models ELS 0018 and 0027 Code Description Action Inlet sensor has a short. Buttons do not function, no heat. Need to replace sensor.
  • Page 8: Remote Operation

    45 (170) 19.2 44.4 50 (189) 22.6 52.2 60 (227) 23.2 53.7 Table E. Pressure Drop for Models ELS 0005 and 0011 Pressure Drop Pressure drop (lpm) in PSI in ft. of Head 15 (57) 20 (76) 25 (95) 30 (114) 12.8...
  • Page 9 122 (50) 49539.7 122 (50) 3628 Table G. Sensor Resistance Models ELS 0005 and 0011 Heater Features Standard Values Element resistance (check with at least one wire lead 9.97 to 11.6 Ω disconnected from each element). Delay in energizing elements (heater starts heating 1 minute 1 minute ±...
  • Page 10: Troubleshooting

    13. TROUBLESHOOTING Problem Cause Solution Nothing happens when the Low flow............1. Check filter, skimmer basket, pump. thermostat is turned on. 2. If a 2-speed pump is used, turn to high speed. 3. Press and hold the knob for 5 seconds. Make sure the flow rate displayed on screen is at least 15 gpm (57 lpm).
  • Page 11: Wiring Diagrams

    AC POWER SUPPLY FLOW SENSOR TRANSFORMER WATER INLET SENSOR, 150K WATER OUTLET SENSOR, 150K REMOTE CONTROL WIRE Figure 6. Wiring Diagram for Models ELS 0005 and 0011 ELEMENT 3 HI-LIMIT 3 ELEMENT 2 HI-LIMIT 2 ELEMENT 1 HI-LIMIT 1 F1 250V/1A...
  • Page 12 ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A.

Table of Contents