Kent Euroclean Rainmaker C Instructions For Use And Parts List

Hide thumbs Also See for Rainmaker C:

Advertisement

Electronic Service
Manuals
This electronic document is provided as a service to our custom-
ers. We do not create the contents of the information contained in
this document. Should you have detailed questions pertaining to
the information contained in this document, you may contact Michco,
or the manufacturer which provided the original information in this
electronic deliverable. Michco's only part in this electronic deliver-
able was the electronic assembly process.
You may contact Michco through the following methods:
Phone (517) 484-9312 or (800) 331-3339 MI, OH, IN only
2011 N. High St. -- Lansing, Michigan -- 48906
Fax: (517) 484-9836
Email: CustServ@Michco.com
Web site: www.Michco.Com
Parts Web site: www.FloorMachineParts.Com
Order Parts on Line at:
www.FloorMachineParts.Com
Directly to Parts & Service:
By Email:
Shop@Michco.com
By Fax: (517) 702-2041
By Voice: Use numbers above.
Serving the Cleaning Industry Since 1922
Notice: All copyrighted material remains property of original owners, all trademarks are property of respective
owners. Manuals are subject to Manufacturer's reproduction limitations. Originals or reproductions were provided
by manufacturers through a request. We make no warranty as to the correctness of information provided in this
document and you assume all risk.

Advertisement

Table of Contents
loading

Summary of Contents for Kent Euroclean Rainmaker C

  • Page 1 Electronic Service Manuals This electronic document is provided as a service to our custom- ers. We do not create the contents of the information contained in this document. Should you have detailed questions pertaining to the information contained in this document, you may contact Michco, or the manufacturer which provided the original information in this electronic deliverable.
  • Page 2 Rainmaker ™ Instructions for use and parts list Kent/Euroclean MODEL 56649980 06/03 revised 11/03 Form Number 56041562...
  • Page 3: Parts And Service

    INTRODUCTION This manual will help you get the most from your Kent/Euroclean Rainmaker C. Read thoroughly before operating the machine. NOTE: Bold numbers in parenthesis indicate an item illustrated on page 7. This product is intended for commercial use only. PARTS AND SERVICE Repairs, when required, should be performed by your authorized Kent/Euroclean Service Center, who employs factory-trained service personnel, and maintains an inventory of Kent/Euroclean original...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices other than normal residential housekeeping purposes. When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using this appliance.
  • Page 5: Consignes De Securite Importantes

    CONSIGNES DE SECURITE IMPORTANTES Cette machine ne convient qu´à un usage industriel, par exemple dans des hôtels, écoles, hôpitaux, usines, boutiques et bureaux et autres à l´exclusion de tout usage de maintenance résidentielle normale. L’utilisation d’un appareil électrique demande certaines précautions LIRE TOUTES LES INSTRUCTIONS AVANT DE FAIRE FONCTIONNER (CET APPAREIL) AVERTISSEMENT! Pour réduire les risques d’incendie, de choc électrique ou de blessure:...
  • Page 6: 120Vac Grounding Instructions

    120VAC GROUNDING INSTRUCTIONS This appliance must be grounded. If it should electrically malfunction, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 7: Instructions Visant La Mise À La Terre (120Vac)

    INSTRUCTIONS VISANT LA MISE À LA TERRE (120VAC) Cet appareil doit être mis à la terre. En cas de défaillance ou de panne éventuelles, la mise a la terre fournit au courant un chemin de moindre résistance qui réduit le risque de choc électrique. Cet appareil est pourvu d’un cordon muni d’un conducteur de terre et d’une fiche avec broche de terre.
  • Page 8: Know Your Machine Descriptions

    KNOW YOUR MACHINE KNOW YOUR MACHINE DESCRIPTIONS Operator Handle (1) - Operator holds this to move the machine from one location to another. Lift Handle (2) - Operator grasps this handle when lifting the machine. Solution Tank Lid (3) - Fill Solution Tank here with warm water and chemicals. Recovery Tank Lid (4) - The Recovery Tank can be flushed out by running clean water into this opening with the Recovery Tank Drain Hose open.
  • Page 9: Wiring Diagram

    SWITCH PLATE DESCRIPTIONS Vacuum Switches (1 and 2) - These switches each turn one vacuum on and off. The switches will light when ON. Pump Switch (3) - This switch turns the pump on and off. The switch will light when ON. ➁...
  • Page 10: Operation

    OPERATION Inspect the machine, hoses, and cleaning tool(s) for cleanliness and completeness. Fill the solution tank with warm water. Using warm water may be a benefit in cleaning ° ° effectiveness, but do not use hot water (above 140 F / 60 C) in the tank.
  • Page 11: Use And Maintenance

    USE AND MAINTENANCE Use only liquid chemicals with a pH between 6 and 9 at the recommended mix ratios. Improper chemicals, or improperly mixed chemcials, can cause possible damage to the pump, seals, and other components. Turn the pump “off” when the solution tank is low on fluid. Do not let the pump run dry. Regularly clean any mineral or chemical deposits in the heat exchanger, lines and pump with a mild acid descaler.
  • Page 12 NOTES: FORM NO.56041562 / Rainmaker C - 11 ™...
  • Page 13 12 - FORM NO. 56041562 / Rainmaker ™...
  • Page 14: Part List

    Gasket, 7 Ft (Quick Disconnect Kit) (Quick Disconnect Kit) (Quick Disconnect Kit) (Quick Disconnect Kit) (Quick Disconnect Kit) 56649986 Label, Kent Euroclean (Quick Disconnect Kit) (Quick Disconnect Kit) (Hardware Kit) (Hardware Kit) 56102836 Washer, Brass (Quick Disconnect Kit) (Quick Disconnect Kit)
  • Page 15: Technical Specifications

    TECHNICAL SPECIFICATIONS Vacuum Motor: Two, 2-Stage Water lift: 150” Air Flow: 100 cfm Amp Draw: 15 amps Tank Construction: Rotationally molded polyethylene Solution Tank Capacity: 14 Gal. (53 L) Recovery Tank Capacity: 12 Gal.(45.4 L) Application Flow: 100 psi Solution Hose Length: 15 ft.
  • Page 16 NOTES FORM NO.56041562 / Rainmaker C - 15 ™...
  • Page 18 VACUUM BALL-FLOAT SYSTEM TROUBLESHOOTING (120V) NOTE: The motors on these extractor models are controlled by AC voltage passing through the ON/OFF switch. VACUUM MOTOR NOT RUNNING: 1. Always unplug the machine before working on the wiring system. 2. Open the machine to look for damaged or disconnected wires leading to the vac motor. 3.
  • Page 19 TESTING THE MOTOR DIRECTLY TO AC VOLTAGE: 1. Unplug the power cords. 2. Cut both the power wires leading from the vacuum motor, several inches from the motor itself. Leave enough length for reconnecting the wires. See Figure 2 below. 3.
  • Page 20 VACUUM BALL-FLOAT SYSTEM TROUBLESHOOTING AquaPro (120V) NOTE: The motors on these extractor models are controlled by AC voltage passing through the ON/OFF switch. VACUUM MOTOR NOT RUNNING: 1. Always unplug the machine before working on the wiring system. 2. Open the machine to look for damaged or disconnected wires leading to the vac motor. 3.
  • Page 21 TESTING THE MOTOR DIRECTLY TO AC VOLTAGE: 1. Unplug the power cords. 2. Cut both the power wires leading from the vacuum motor, several inches from the motor itself. Leave enough length for reconnecting the wires. See Figure 2 below. 3.
  • Page 22: Vacuum Motor Replacement

    VACUUM MOTOR REPLACEMENT AquaPro (120V & 240V) BEFORE BEGINNING REPAIRS: Unplug the machine, empty all water from the tanks, open the latches and prop the tanks up. VACUUM MOTOR REMOVAL: 1. Check to be sure the machine is unplugged. 2. Cut the ground wires (green/yellow) from the vac motor, about 3 inches from the insulated butt connector.
  • Page 23 Solution Exhaust Lines Hose FIGURE 2 FIGURE 3 Exhaust Hose STEP 5: Remove 3 nuts holding motor to mount- ing bolts. (3rd nut not shown). Heat Exchanger STEP 6: Loosen hose Vacuum bracket and slide Motor exhaust hose down. 5. Remove the 3 nuts which hold the motor to the mounting bolts. See Figure 2 above. 6.
  • Page 24 LOW VACUUM LIFT PRE-TROUBLESHOOTING ALL MACHINES (120V & 240V) Before beginning to troubleshoot the vacuum system on your machine, check all the possible causes of low vacuum lift listed below. ALL EXTRACTORS: 1. The vacuum inlet filter in the recovery tank is dirty. 2.
  • Page 25 100 & 150 PSI PUMP ADJUSTMENT Rainmaker and AquaPro (120V & 240V) This pump has an adjustable pressure switch. If the pump pulsates during operation, see step “A” below. If the pump does not shut off after spraying, see step “B” below. IMPORTANT NOTICE: Older pumps may pulsate when not spraying.