Voltage Attenuation At Sine Ripple Frequencies - EM TEST VDS 200 Series Manual For Operation

Voltage drop simulator pulses 2b, 4
Table of Contents

Advertisement

EM TEST

5.10.2. Voltage attenuation at sine ripple frequencies

Using an individual amplitude control with sine ripple, the user must compensate the attenuation of the amplifier
frequency bandwidth. The table below shows the attenuator factor for frequencies range 1kHz to 100kHz.
The ripple voltage must respect the voltage limitation (see chapter 4.7)
Correction table for sine ripple 1kHz to100kHz
Frequency
Attenuation
[kHz]
1
1.0044
2
0.9924
3
0.9759
4
0.9554
5
0.9308
6
0.9033
7
0.8737
8
0.8420
9
0.8087
10
0.7748
11
0.7409
12
0.7067
13
0.6727
14
0.6398
15
0.6076
16
0.5766
17
0.5466
18
0.5181
19
0.4911
20
0.4652
21
0.4409
22
0.4177
23
0.3959
24
0.3754
25
0.3562
Attenuation curve according the correction table
The amplitude at sine ripple is compensated in manual operation by the VDS 200N firmware.
Manual for Operation
Frequency
Attenuation
[kHz]
26
0.3379
27
0.3208
28
0.3049
29
0.2897
30
0.2756
31
0.2624
32
0.2499
33
0.2380
34
0.2271
35
0.2166
36
0.2067
37
0.1974
38
0.1888
39
0.1806
40
0.1728
41
0.1654
42
0.1583
43
0.1519
44
0.1456
45
0.1397
46
0.1340
47
0.1287
48
0.1237
49
0.1189
50
0.1142
Frequency
Attenuation
[kHz]
51
0.1099
52
0.1059
53
0.1017
54
0.098
55
0.0944
56
0.091
57
0.0876
58
0.0846
59
0.0816
60
0.0785
61
0.0757
62
0.073
63
0.0707
64
0.0684
65
0.066
66
0.0636
67
0.0615
68
0.0595
69
0.0576
70
0.0558
71
0.054
72
0.0522
73
0.0505
74
0.0491
75
0.0474
V 5.19
VDS 200 Series
Frequency
Attenuation
[kHz]
76
0.0461
77
0.0447
78
0.0436
79
0.0422
80
0.0409
81
0.0397
82
0.0387
83
0.0376
84
0.0365
85
0.0356
86
0.0347
87
0.0337
88
0.0328
89
0.032
90
0.0313
91
0.0304
92
0.0295
93
0.0289
94
0.0282
95
0.0275
96
0.027
97
0.0264
98
0.0259
99
0.0255
100
0.0249
43 / 57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents