Functions; Sine Wave - EM TEST VDS 200 Series Manual For Operation

Voltage drop simulator pulses 2b, 4
Table of Contents

Advertisement

EM TEST
3.3.4.

Functions

3.3.4.1. Sine wave

Parameters:
Vb
0.0V
Vp
0.25V
t1
0.1s
f1
0.001kHz
t2
1.0s
n
1
I
1.0A
Frequency behavior
Firmware from version 4.20a18...25
16Vpp up to 25kHz
10Vpp up to 30kHz
6Vpp up to 50kHz
Firmware version 4.18a01...17 and higher
12Vpp up to 10kHz
10Vpp up to 30kHz
6Vpp up to 50kHz
Firmware up to version 4.17
5Vpp up to 30kHz
>30kHz linear decrease to 3.5V at 50kHz (see diagram)
For Frequency >50kHz to 100kHz the VDS output voltage must be limited to max. 3Vpp.
Therefore the analogue input signal must be limited to max. 0.7Vpp !
Manual for Operation
-
30.0V
(60.0V)
-
6.0V
-
99.9s
-
50.00kHz
-
999.9s
30'000 / endl.
-
-
15//30//50//100A
manufactured. 2007 or later
Limitations
Vn + Vp <= 30.0V (60.0V)
Vn - Vp = 0.0V
For frequency setting see the following limitations
max 6Vpp up to the full 50kHz range
max 16Vpp up to 25kHz
f< 100Hz  1.2Hz
V 5.19
VDS 200 Series
24 / 57