LC-13SH1E LC-15SH1E SERVICE MANUAL SY4C2LC13SH1E LCD COLOUR TELEVISION LC-13SH1E LC-15SH1E MODELS In the interests of user-safety (Required by safety regulations in some countries) the set should be re- stored to its original condition and only parts identical to those specified should be used.
LC-13SH1E LC-15SH1E IMPORTANT SERVICE SAFETY PRECAUTION Ë Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow: • Connect the resistor connection to all exposed metal...
Page 4
LC-13SH1E LC-15SH1E Precautions for using lead-free solder 1 Employing lead-free solder "MAIN PWB" of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on the PWBs and service manuals. The alphabetical character following LF shows the type of lead-free solder.
4.1 kg, w/o accessories As a part of policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement without prior notice. The performance specification figures indicated are nominal values of production units. There may be...
3. Remove the cabinet B after opening from the direction of an arrow. 4. Detach the connector from each PWB. Cabinet A Cabinet B ~ Note: For the LC-13SH1E, disconnect Stand the AC cord from the PWB. Operation PWB SC4201...
Page 10
LC-13SH1E LC-15SH1E 5. Remove the 2 lock screws from the main PWB and undo the hooks a. Detach the chassis frame, together with its terminals, from the main PWB. 6. Remove the 2 lock screws from the sub PWB and undo the hooks b, c and d. Detach the chassis frame together with its terminals, from the sub PWB.
Page 11
LC-13SH1E LC-15SH1E » Precautions in handling the LCD panels 1. Work in a clean room (with humidities below 50%). 2. Be sure to wear an anti-static armband. 3. Handle the panels on an electro-conductive mat. 4. Be careful not to fall, shake and shock the panels.
Page 12
LC-13SH1E LC-15SH1E » Precautions at the time of the side B(back) service of main and sub unit. 1. Remove only SC1203 of the FFC for connection between Main unit (SC1203) and LCD panel, and connect the extended cable (QCNW-A553WJZZ) for service.
LC-13SH1E LC-15SH1E ADJUSTING PROCEDURE OF EACH SECTION The best adjustment is made before shipping. If any position deviation is found or after part replacement is performed, adjust as follows. Preparation for adjustments Use a stable AC power source. LC-13/15SH1E AC Power : 230V 1.
Page 14
LC-13SH1E LC-15SH1E 5. Adjustment 5-1. RF AGC adjustment 1) Feed the colour bar signal. 2) In Adjustment Mode, select the RF AGC AUTO ("OFF") and press the " RIGHT" cursor key to start the adjustment. 3) Automatic adjustment is complete when it display "OK" is displayed.
Page 15
LC-13SH1E LC-15SH1E 7. Lamp error detection 7-1. Functional description This LCD colour television has a function (lamp error detection) to be turned OFF automatically for safety when the lamp or lamp circuit is abnormal. If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the followings occur.
Page 16
LC-13SH1E LC-15SH1E 8. Hotel mode 8-1. How to enter the Hotel mode. 1) Turn on the power and enter the Adjustment Process mode. 2) Using the "UP" or "DOWN" cursor key on the remote controller, select the Hotel mode. 3) Using the "RIGHT" cursor key on the remote controller, change the setting from "0" to "1". Now the Hotel mode shows up.
Page 17
LC-13SH1E LC-15SH1E 9. Software Loading 1) Upgrading the software or after replacement of IC151, IC501 or Main PWB, make sure to upload the processors with updated software. 2) Please use the dedicated Interface JIG (JIGINF-001) and supplied programs for upgrading the software.
Page 18
LC-13SH1E LC-15SH1E 4) First click [SST / ATMEL] and then follow by [Identify] to identify the flash memory. Confirm the item below in Comment Window. 5) Click [Select Intel HEX File …] to open the source files. The source file name are "Sedna_Sharp****.hex"...
Page 19
LC-13SH1E LC-15SH1E 9) Finally click [Restart System] to initialize. Confirm "Reset done" in Comment Window. 10) Power OFF the set by unplugging AC Cord, remove the JIG from the plug and wait for 1 minute before power ON again. Notes: If any error occur during any process, power OFF the set and repeat the all the process again. If these still fail, please erase Main Software and repeat the whole process again.
Page 20
LC-13SH1E LC-15SH1E 4) First click [Enter ISP Mode] then click [Send]. If the following window appear, click [Yes] Confirm ISP status "Ready". If "Entering ISP is not successful" occur, repeat step No. 4) again. If still fail, unplug the AC cord and repeat from step No.
Page 21
LC-13SH1E LC-15SH1E 6) Next click [Write Flash] and load the source file by clicking [Browse]. The source file name are "LC20SH1_****.hex". Once the data is loaded successfully click [Send]. Confirm the Program, PK26 & Character are all "OK" and ISP status is "Ready".
LC-13SH1E LC-15SH1E DESCRIPTION OF SCHEMATIC DIAGRAM VOLTAGE MEASUREMENT CONDITION: 1. The voltages at test points are measured on the stable supply voltage of AC 220–240V. Signals are fed by a colour bar signal generator for servicing purpose and the above voltages are measured with a 20k ohm/V tester.
Part No. Description Code Ref. No. Part No. Description Code PARTS LIST DUNTKC857WE06 (LC-13SH1E) DUNTKC857WE05 (LC-15SH1E) PARTS REPLACEMENT SUB UNIT INTEGRATED CIRCUITS Replacement parts which have these special safety characteristics IC3301 VHiAN17821A-1 J AN17821A identified in this manual; electrical components having such features IC7701 VHiSTRW67652E J I.C.
Page 65
LC-13SH1E LC-15SH1E Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKC857WE06 (LC-13SH1E) R6717 VRS-CY1JF333JY J 33k 1/16W Metal Oxide DUNTKC857WE05 (LC-15SH1E) R6722 VRS-CY1JF471JY J 470 1/16W Metal Oxide R6723 VRS-CY1JF824JY J 820k 1/16W Metal Oxide SUB UNIT (Continued)
Page 66
LC-15SH1E Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKC857WE06 (LC-13SH1E) DUNTKC858WE06 (LC-13SH1E) DUNTKC857WE05 (LC-15SH1E) DUNTKC858WE05 (LC-15SH1E) SUB UNIT (Continued) OPERATION UNIT DIODES P7701 QCNCMA012WJZZ J Plug, 15-pin P7702 QPLGN0269GEZZ J Plug, 2-pin (AC INPUT Termial) AB...
Page 67
LC-13SH1E LC-15SH1E Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKC859WE06 (LC-13SH1E) DUNTKC860FM05 (LC-13SH1E) DUNTKC859WE05 (LC-15SH1E) DUNTKC860FM04 (LC-15SH1E) R/C, LED UNIT MAIN UNIT TRANSISTORS TUNER NOTE: THE PARTS HERE SHOWN ARE SUPPLIED AS AN Q4001 VSKRC104S//-1Y J KRC104S ASSEMBLY BUT NOT INDEPENDENTLY.
Page 72
CABINET AND MECHANICAL PARTS RCORFA032WJZZ J Ferrite Core GCOVHA069WJKA S AC Holder (LC-13SH1E) LHLDK0002PEK0 J AC Cord Holder QACCZA019WJPZ J AC Cord (LC-13SH1E/E å (F)/E(I)/E(R)) CCABAA755WJ01 S Cabinet A Ass’y QACCBA024WJPZ J AC Cord (LC-13SH1E(K)) Not Available – Cabinet A —...
Page 73
LC-13SH1E LC-15SH1E CABINET AND MECHANICAL PARTS Oniy for LC-15SH1E Operation PWB Oniy for LC-13SH1E 5-2-6 R/C, LED PWB 5-2-5 5-2-3 5-2-1 5-2-4 5-2-2 3-1-3 3-1-1 3-1-2 Sub PWB Main PWB...
Page 74
LC-13SH1E LC-15SH1E Ref. No. Part No. Description Code Ref. No. Part No. Description Code CABINET AND MECHANICAL PARTS TLABSA029WJZZ J GOST Label (LC-15SH1E(R)) (LC-15SH1E) RCORFA032WJZZ J Ferrite Core RCORF0103CEZZ J Ferrite Core PSPAZA677WJZZ S Spacer, x1 CCABAA754WJ01 S Cabinet A Ass’y...
Page 75
(NOT REPLACEMENT ITEM) å QACCBA016WJPZ J AC Cord (LC-15SH1E(K)) SPAKCB717WJZZ – Packing Case(LC-15SH1E) — å QACCKA006WJPZ J AC Cord (LC-15SH1E/E SPAKCB718WJZZ – Packing Case(LC-13SH1E) — (F)/E(I)/E(R)) SPAKPA465WJZZ – Wrapping Paper — RRMCGA339WJSA S Wireless Remote Control (LC-15SH1E) TiNS-B517WJN2 S Operation Manual SPAKPA466WJZZ –...