2. Programming the System Settings

All operating panel system parameters are set
in plain text. This offers the advantage of the
parameter settings being documented in an
understandable language together with the
message texts. The system settings appear in
front of the message 0.
The presettings do not have to be typed in letter
by letter! Connect the operating panel to your
programming unit and select the menu item
Read text display" in the EBELT software.
The default setting (or the currently
2.1 Valid System Settings
Example: BEST224-12-Z
*Binär
*Drucker
*IBM Zeichensatz
*Helligkeit: 80%
*Scrollzeit: 3,2s
*Blink-Ein: 0,3s
*Blink-Aus: 0,2s
*Ko-M Tast: 10 LED: 02
*Ta-Mode: BBBBBBBB MMMM
*Ta-Led: IIIIIIII EEEE
*Ta-Farbe: RGRGRGR RGRG
*Ta-Blink: EAEAEAEA AEAE
*
BEST 224 ready for operation
* Binär
The binary system is used for message text
selection (in contrast to the BCD system). The
possible number of message texts is 1000 + 23
system messages.
* BCD
The BCD (binary coded decimal number)
system is used for message text selection. The
number of message texts is therefore limited to
400.
* Cpm
The first internal character set is loaded in
accordance with the ASCII-table used with
CPM.
* IBM
The first internal character set is loaded in
accordance with the character table used with
the IBM PC.
Programming the Operating Panel Editon 2/94
programmed setting) is supplied, allowing you
to simply make modifications as desired.
The following parameters can be set:
Message text selection binary/BCD
Internal character set CPM/IBM
Display brightness (for LED displays)
Scroll and blink times
Communication flag for keys and LEDs
Keyboard characteristics (push-button keys or
latch-down keys)
LED characteristics (internal/external/color)
Printer connection on/o
* Scrollzeit: 3,2
When a message with more than 2 lines is
(1)
programmed and to be displayed on a 2-line
(12)
display, the display will automatically begin to
(2)
scroll the text one line at a time. This scroll time
(3)
can be set to a time between 0,1 and 6,3 s.
(4)
(5)
* BLink-Ein: 0,2
(6)
The Blink-On duration can be set to a time
(7)
between 0,1 to 6,3 s.
(8)
(9)
* BLink-Aus: 0,2
(10)
The Blink-Off duration can be set to a time
(11)
between 0,1 to 6,3 s.
* Ko-M Tast: 10 LED: 02
Communication flag for F-keys and LEDs
Exception: S5 is parameterized in the data
(1)
handling block.
* Ta-Mode/LED/Farbe/Blink
The following lines vary with the different
operating panels depending on the number of
function keys and the assigned LEDs. For
(1)
operating panels with only 12 function keys,
they are defined in one line. For operating
panels with more function keys, a new line is
used for every 8 function keys.
* Ta-Mode: MBBBMMMM MBMB
(2)
The key mode can be defined separately for
every key. M stands for monostable or push-
down key, B stands for bistable or latch-down
key. The sequence is read from left to right.
(2)
* Ta-LED: EIIIIEEE IEIE
LEDs in the keys can be activated either
internally (directly by the key) or externally by
the PLC. E stands for externally, I stands for
internally. The sequence is read from left to
right.