Emerson ATCA-7368 Installation And Use Manual page 180

Table of Contents

Advertisement

FRU Information and SDR Summary
Table 8-28 1.5V (continued)
Feature
Base Unit
Rearm mode
Hysteresis Support
Threshold Access
Support
Event Message Control
Nominal Reading
Upper non-recoverable
threshold
Upper critical threshold
Upper non-critical
threshold
Lower non-recoverable
threshold
Lower critical threshold
Lower non-critical
threshold
Reading Definition
Table 8-29 1.2V
Feature
Sensor Name
Sensor LUN
Sensor Number
Entity ID
Sensor Type
180
Raw Value
0x04
0x01
0x02
0x02
0x00
0x9A
0xAB
0xA3
0x00
0x89
0x90
0x00
Analog reading byte
Raw Value
1.2V
0x00
0x18
0x14
0x02
ATCA-7368 Installation and Use (6806800M12C)
Description
Volts
Auto
Readable and settable
Readable and settable
Per Threshold/Discrete
State
1.5
1.7
1.6
(unspecified)
1.4
1.3
(unspecified)
Analog sensor reading
Description
-
-
-
power module / DC-to-DC
converter
Voltage

Advertisement