R E A S S E M B L Y H I N T S & T I P S
Tip 10
For
proper
alignment
magnetic field, align the end of the
shaft flush with the inside bottom of
the magnet assembly.
Model Size
1/2 HP
Outer casing bolts
2.9 (26.0)
Drain Plug
-
Bracket to Motor
7.9 (69.5)
Bracket to Base
7.9 (69.5)
NOTE: Additional assistance for the maintenance, repair or assembly of a T-MAG™ pump
is available from the factory. If you have any additional questions regarding service or
repair, contact T-MAG™ in the U.S. at (855) 848-TMAG.
Tip 11
of
the
Before installation of the previously
assembled liquid casing of the
pump, use an adhesive tape to
remove ALL metal fragments or
debris that may be on the outside of
the magnet housing. Failure to do
so will result in premature wear of
the rear casing of the pump.
1 HP
2 HP
2.9 (26.0)
2.9 (26.0)
2.9 (26.0)
2.0 (17.3)
2.0 (17.3)
2.0 (17.3)
7.9 (69.5)
7.9 (69.5)
7.9 (69.5)
7.9 (69.5)
7.9 (69.5)
7.9 (69.5)
Tip 12
When installing the foot plate to the
mounting bracket of the pump, be
sure to use one washer between
the base and the bracket and one
between the nut and the top of the
bracket.
3 HP
5 HP
2.9 (26.0)
2.0 (17.3)
7.9 (69.5)
7.9 (69.5)