Download Print this page

T-MAG AMX Series Engineering, Operation & Maintenance page 24

Advertisement

P U M P D I S A S S E M B L Y
Step 4
Remove and inspect outer casing o-
ring for damage or wear. Replace as
necessary.
Step 7
Remove
the
bolts
holding
mounting bracket to the motor.
Use caution when removing as the
motor is heavy and may tip causing
injury.
Step 5
Carefully
remove
magnet assembly. Use caution not
to pinch fingers as the impeller will
show resistance being removed due
to the magnetic field of the outer
magnet.
Step 8
Carefully
remove
the
bracket from the motor, exposing
the outer magnet.
22
Step 6
the
impeller/
Remove the rear casing of the liquid
end from the mounting bracket.
Inspect for wear inside or out, as
this may be a sign of misalignment
of the impeller or outer magnet.
Step 9
the
mounting
If it is necessary to remove the outer
magnet from the motor, use a hex
wrench to remove the two (2) set
screws from the shaft end. NOTE:
The
outer
screws on some T-MAG™ Mag-
Drive pumps must be accessed
through the adjustment port located
under the mounting bracket.
magnet
adjustment

Advertisement

loading

This manual is also suitable for:

Tm4 seriesTm6 seriesTm10 series