Page 1
Manual Digital optical transmitter for Ethernet (10/100 Mbit) signals Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, www.reliantemc.com...
Page 2
Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, www.reliantemc.com...
The system also is optimized for low noise emission. Power is supplied by internal NiMH-batteries which make the system easy to use. The optoLAN is prepared for the use of external batteries (with optional battery pack). Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, www.reliantemc.com...
2 (+) and pin 4 (GND). An external supply (6…8V, 0.5A) system might get can be connected to pin 3 (+) and pin 4 (GND). Use only power supplies damaged! which are certified by mk-messtechnik. Pinning of charge- / buffer connector Fig. 4.1: Pinning of charge- / buffer connector...
Page 6
Date: optoLAN 11/15/11 Page: 6 Manual Do not use charger The included chargers are not meant to power the transceivers during or power supply operation. The transceiver outside the shielded room can be run with an during EMI-test! external power supply (optional). The internal transceiver can be run with an external battery, if needed (optional).
Date: 11/15/11 Manual Page 7 Trouble shooting The following trouble shooting list is provided to assist you while having problems. It might let you use the system again without a long down time: Error: Possible reasons: Solution: No or erroneous...
Date: optoLAN 11/15/11 Page: 8 Manual Accessories / Options Part Order number Comment Optical fiber LWL-2-xm x = length in m, duplex External batteries BP-60 6V/4Ah Connector cable for AK-BP Length approx. 15cm BP-60 Charger with connector plugs CH-5 Standard charger...
11/15/11 Manual - Appendix Page A1 Appendix: Details and operation The following chapter describes special details of the optoLAN system for the transmission of ethernet signals. The system consists of two transceivers. Housing and connectors / switches Fig. a.1 shows the front side of the transceivers with connectors and...
Page 10
(BP-60) with connector cable or a power supply certified by mk- cables provided messtechnik. The external supply can be connected to the system any time from mk- (parallel). The connection to the internal battery is decoupled with a diode.
Need help?
Do you have a question about the optoLAN and is the answer not in the manual?
Questions and answers