Four Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet
1. General description
TETRA 43x0 (4310 for multimode, and 4350 for single-
mode) digital-optical multiplexer/demultiplexer systems
can transmit signals through four unidirectional,
independent composite video channels and two audio,
two contact closure, four data channels, and Fast
Ethernet, all bidirectional, independent and transparent,
using one single-mode optical fiber per system. Video
and data/audio input signals are sampled at a rate of 15
MHz and digitized with 10-bit accuracy.
TETRA 43x0 TX transceivers convert and combine
composite video, audio, data, contact closure, and
Ethernet signals into one digital stream, which in turn is
converted into an optical signal, using a wavelength of
1310 nm. The TETRA 43x0 TX will also convert and
decode an incoming 1550 nm optical signal carrying a
digital stream of data, audio and contact closure signals.
A TETRA 43x0 RX transceiver receives, converts and
decodes the video and other signals arriving through the
optical fiber. It will also convert and combine
audio/data/contact closure, and Ethernet inputs, then
transmit
this
information
complementary TX, using an optical wavelength of
1550 nm.
The composite video channels can all individually be set
to transparent mode (i.e. video clamping off), and the
video channel operation mode and several switching
functions are accessible through software, using the
SmartNet management system (SNM). Several aspects
of data and audio interfacing can be controlled by means
of circuit board dip switches and jumpers.
The data port D1 and D3 interfaces can be set for
compatibility with RS-422, RS-485 2W, RS-485 4W,
and Manchester PTZ (bi-phase) data. In addition, using
modified cabling, the RS-422 interface can be set up for
digital current loop/TTY applications. Data ports D2 and
D4 are set up for adjustment free RS-232 operation.
The inputs of the 4-wire audio interfaces can be set to
high or low impedance, balanced or unbalanced. Contact
closures are normally open.
Front panel status LEDs indicate DC power good, video
signal presence, local and remote link synchronization
and data activity (see section 2).
TETRA 43x0 units are double-width (14TE) Eurocard-
sized modules and should be used in combination with
MC 11 or similar power supply cabinets, the EB-2
versions of these cabinets offering SNM management.
© Siqura 2012
Version 1.5 (071708-1e)
TETRA43x0TX&RX (MW07SP2)
TETRA 43x0
USER MANUAL
optically
towards
the
Figure 1. Tetra 43X0 RX front Panel. TX panels look
similar, with video inputs instead of outputs. See table 1.
Stand-alone models (/SA option, see supplementary
/SA-2 manual) need separate 12 VDC power supplies. A
Siqura PSA 12 DC-25 would be suitable.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TETRA 4310 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siqura TETRA 4310

  • Page 1 /SA-2 manual) need separate 12 VDC power supplies. A and data activity (see section 2). Siqura PSA 12 DC-25 would be suitable. TETRA 43x0 units are double-width (14TE) Eurocard- sized modules and should be used in combination with MC 11 or similar power supply cabinets, the EB-2 versions of these cabinets offering SNM management.
  • Page 2 2. Indications and connectors Table 1 lists the front panel features of TETRA 43x0 modules (refer to figure 1). Connector pin assignments are detailed in section 6. TETRA 43x0 TX  Optical video/data out, optical (SC/UPC connector) data in  (BNC connector) 1-8 Composite video in TETRA 43x0 RX...
  • Page 3 position, the RS-485 input is unterminated. When both Interface port D1 port D3 type  are set in the ON position, the differential input is RS-422 terminated with 120 ohms resistance. RS-485 4W For RS-485 installations, there might be anywhere from RS-485 2W OFF OFF OFF 2 to 32 RS-485 devices attached to the differential bus.
  • Page 4: Installation

    Ethernet Mode Select: The default settings for Ethernet fiber equipment using appropriate cabling. operation (all switches OFF) enables automatic speed CLEAN THE OPTICAL FIBER CONNECTORS and half duplex/full duplex negotiation. However, the PRIOR TO INSERTION INTO THE OPTICAL PORT. Ethernet Mode Select dip-switch can be used to force the For long electrical links, twisted pair wiring should be Ethernet port into one particular mode by setting the used.
  • Page 5: Care And Maintenance

    EN 55022 (Class B) *In the following Optical Specifications section: FCC 47 CFR 15 (Class B) Electrical a) 4310 refers to an TETRA 4310 TX and TETRA Supply voltages 12 (/SA: 11-19) 4310RX pair for multimode operation b) 4350 refers to an TETRA 4350 TX and TETRA Power consumption <7.2 (cont.)****...
  • Page 6 The installer is responsible for ensuring that the label depicted Siqura assumes no liability for the customer’s failure to comply below (background: yellow; border and text: black) is present in with any of these safety requirements.
  • Page 7: Product Disposal

    All power supplies or power supply circumstances may cause interference to other equipment or a cabinets available from Siqura comply with these SELV requirements. performance decrease due to interference radiated by other equipment. In such cases, the user will have to take appropriate measures to reduce such interactions between this and other equipment.