Miele MasterCool K 2611 Vi Operating And Installation Instructions page 40

Table of Contents

Advertisement

Building in the appliance
 Adjust the front feet  with a ratchet
(attachment: 5/16" (8 mm) socket) or
a TX 20 screwdriver.
Tip: Proceed carefully when adjusting
the feet, alternating between the left
and right feet.
40
 Place a spirit level across the installa-
tion aids  on the appliance door to
check the appliance's alignment.
 Unscrew the feet  and  on both
sides at least until the marking on the
toe-kick is aligned with the required
1 1/4" (32 mm) on the spacer . The
standard dimension of 1 1/4" (32 mm)
relates to a niche height of
84" (2,134 mm).
It is important to align the feet to a
height of at least 1 1/4" (32 mm) so
that the appliance's ventilation works
properly via the toe-kick.
Risk of damage!
Unscrew the feet only until the
marking on the toe-kick is aligned to
a maximum of 2 7/16" (62 mm) (max.
niche height of 85 3/16" (2,164 mm)).
Otherwise the rear foot adjustment
will be damaged.
 Check the alignment of the appliance
again using installation aids  and
the spirit level.

Hide quick links: