nFormatIon on the unIt
Before operating the unit for the first time, please check that all contents have been delivered and
that the line voltage is correct. The supplied power adapter (A) is an electronic power supply
unit intended for an operating voltage of 100 V~ to 240 V~. Should you require a different
plug type for the operation of the device, you can purchase it from Promed. To change the
plug type, press the release (M) and pull the power plug (N) from the power supply unit (A).
Take the required power plug (N) and push it back into the power supply unit (A).
• The Promed 1030 device is outstandingly suitable for manicure with the abrasive wheels
provided for this purpose, but especially for use in nail technique (nail design).
• The Promed 1030 unit uses a high performance motor. The electronic speed control
is used to smoothly set the speed of the grinding head. The unit can rotate clockwise or
counterclockwise (reversible).
• The grinding head holder is able to fixate all commercial grinding heads with standardized
dental size shafts of (ø 2.332 to 2.350 mm / 0.091 - 0.093 inches). Please use only high-
quality grinding heads with a rounded shaft end and a maximal shaft length of 36 mm
(1.26 inches) to guarantee the longest life possible for the grinding head holder!
• If you want to remove the hand piece (J), just insert it in the hand piece holder (G)
provided for this purpose.
• Always make sure that the grinding head does not come in contact with other objects
DE
when you lay the handpiece down. There is a risk of the shaft becoming compressed and
asymmetrical. Asymmetry in the grinding head causes damage to the handpiece!
• Grinding head bits are available at your local specialist retailer or Promed (www.promed.de).
EN
• To ensure hygienic operation, the grinding heads must be disinfected after use.
• The handpiece may only be disinfected using disinfectant wipes.
• Information about suitable disinfectants and products can be obtained from Promed.
For disinfection of instruments and grinding heads:
FR
Promed Pure ID (Product No. 330810)
For disinfection of surfaces and devices:
Promed Pure FD (Product No. 330815)
IT
For disinfection and cleaning of instruments and grinding heads:
Promed UC-50 (Product No. 330210)
• If needed, the power adapter (Product No. 290426) and the handpiece (Product No. 201004)
ES
can be purchased from Promed separately.
Scope of delivery:
NL
1x Device 1030 (item 201001)
1x Handpiece MR10 (item 201004)
1x Power adapter (item 290426)
1x Instructions
RU
Optional accessories:
A foot pedal (Product No. 290004) with an ON/OFF function is available as an accessory.
PL
SE
FI
/ s
CoPe oF DeLIVery
/
aCCessorIes