  • Page 1 E62-DTU (433D30)
  • Page 2: Table Of Contents

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual Content 1.Introduction..................................2 1.1. Brief Introduction........................... 2 1.2. Features..............................2 Operation.................................2 Installation Specifications............................4 3.1. Structure..............................4 3.2. Dimension...............................6 Interface Defination..............................7 4.1. Power interface definition........................7 4.2. RS232 Interface definition........................7 4.3. RS485 Interface definition........................7 Technical indicators..............................
  • Page 3: Introduction

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual 1.Introduction Brief Introduction 1.1. E62-DTU (433D30) is a full duplex wireless data transmission module for point-to-point transmission( Has both RS232 and RS485), transmission power is 100mW, transparent transmission mode, working in 433MHz band.
  • Page 4 Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual First step is to mount antenna, then battery, making sure the dial switch is on its right status. User gets on the power 1、 by choosing either VCC/GND or power adapter. Using USB-(RS232) converter or USB-RS(485) converter or other way to link computer and DTU.
  • Page 5: Installation Specifications

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual User needs to open the mode switch first before link DTU with computer if the user want to modify parameters. 4、 Firing up (E62-DTU parameter configuration application) to modify related parameters. E62-DTU 数传电台配置软件...
  • Page 6 Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual Pin NO. Name Function Description DB-9 female socket RS-232 interface Standard RS-232 interface Standard RS-485 interface and pressure line 3.81 terminal block RS-485, power interface power interface PWR-LED Power LED Red, lit when the power is on...
  • Page 7: Dimension

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual Dimension 3.2. Unit:mm Chengdu Ebyte Electronic Technology Co,;Ltd Copyright ©2012–2019,...
  • Page 8: Interface Defination

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual 4. Interface Defination Power interface definition 4.1. Users can choose ⑥ DC power interface, using the power adapter supply with the interface of the 5.5mm outer diameter , 2.5mm diameter ; Also choose the VCC and GND terminal power supply, only choose any one of the power supply is OK;...
  • Page 9: Technical Indicators

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual The power supply negative pole is connected to the system Crimping power interface, negative ground and the housing 485_B RS-485 interface, interface B The RS-485 interface B is connected to the device interface B...
  • Page 10: Frequency Range And Channels

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual Frequency range and channels 5.3. Channel Default frequency Frequency range Model spacing Channels E62-DTU (433D30) 425 ~ 450.5 Full-duplex ★ Note: In the same area when multiple data transceivers are communicating one to one at the same time, it is recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
  • Page 11: Operating Mode

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual 2. The data transceiver cannot receive data which is more than the buffer capacity; 6. Operating mode E62-DTU(433D30) has two operating modes, if low power consumption is not required, transmission mode (mode 0)is recommended for transmission.
  • Page 12: Connection Diagram When Programming

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual 7. Connection diagram when programming Diagrammatic drawing 7.1. Mode Description Configuration Serial port at fixed 9600bps baud rate, Mode 1 mode wireless off, configurable parameters ★ Note: 1.programming can only be carried on in a specific mode(see above), if fails, please confirm the work mode.
  • Page 13: Parameter Setting Instruction

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual application) to modify parameters. Parameter setting instruction 7.2. Parameter Description The serial port baud rate of a wireless data station at work,1200bps~115200bps。 Baud rate Support 8N1:no check ; 8E1:even-check; 8O1:odd-check; Both are 8-bit data bits and 1-bit stop...
  • Page 14: Connection Diagram In Test And Application

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual The internal serial ID of the wireless data transmission modem, regardless of the Modbust Frequency address. Modem with the same station serial ID can communicate with each other, and this hopping ID feature can be used to implement software grouping.
  • Page 15: Practical Application

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual Practical application The data transceiver of CDEBYTE is applied for all kinds of point to point, one point to multiple points wireless data transmission system, such as smart home, Internet of things transformation, power load monitoring, distribution...
  • Page 16: About Us

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-DTU (433D30)user manual to ensure that transceiver working properly. 5. Please do not use it in the working environment beyond the transceiver environmental characteristics , such as high temperature, humidity, low temperature, strong electromagnetic fields or dust larger environment.