Table of Contents

Advertisement

Quick Links

LogiScan-600/800/1100
Standard Application 03000 v3.80
Operating Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LogiScan-800 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aitronic LogiScan-800

  • Page 1 LogiScan-600/800/1100 Standard Application 03000 v3.80 Operating Manual...
  • Page 2 LogiScan-800 LogiScan-600 LogiScan-1100 LogiScan-600/800/1100 Standard Application 03000 v3.80 Operating Manual...
  • Page 3 Telefax: +49 (0) 5251 29816-40 Internet: http://www.aitronic.de E-Mail: info@aitronic.de ___________________________________________________________ Copyright  aitronic GmbH, 2015 All Rights reserved, in particular all extracts which correspond to the translation, the reprint and reproduction by copying or similar methods. Delivery and technical changes are subject to change.
  • Page 4 Extensions for LogiScan-1100 02.05.2011 Description Akku/SIM Card Replacement LogiScan-1100 20.10.2011 Adaption for software version 3.30 (Bluetooth) 05.03.2014 Software update description of devices which are connected via 27.02.2015 Neues Option-Menü-Item „Feldtrennzeichen“ Other Documents asserting with this one • Technical Manual LogiScan-600/800/1100 ____________________________________________________________________ aitronic...
  • Page 5: Table Of Contents

    Choosing an Input Field ................5-8 Closing Entry and storing the Record............5-8 6. System Functions ............6-1 Charging the integrated Accumulator............6-1 Hardware Reset..................6-2 System Menu..................... 6-3 System Error Message „Battery low!“............6-4 7. Battery and SIM Card Changing ........7-1 ____________________________________________________________________ aitronic...
  • Page 6 Cradle for LogiScan-600/800 ..............9-1 Cradle for LogiScan-1100 ................. 9-1 Truck Charging Station for LogiScan-600/800 .......... 9-2 Charging Station for LogiScan-600/800 ............ 9-2 Belt Holder for LogiScan-600/800 ............. 9-2 Accesspoint for DECT RF Network ............9-3 11. Recycling Orders ............11-1 ____________________________________________________________________ aitronic...
  • Page 7 Cable bound Data Transmission ............12-23 DECT Data Transmission..............12-25 GPRS or WLAN Data Transmission............12-27 Activating the SIM Card after PIN Error..........12-29 Bluetooth Communication ..............12-30 Deleting the Data Memory manually ............. 12-31 Logging....................12-33 Test Barcodes ..................12-34 ____________________________________________________________________ aitronic...
  • Page 8: Introduction

    For property- or personal damage caused, directly or indirectly, as a consequence of using our devices or software, the company aitronic cannot be held for liability. This handbook as well as parts of it may not be copied, broadcast or transferred, without the prior consent of the company aitronic.
  • Page 9: Security Hints

    The necessary safety labels can be found under the laser light window. Never try to open any of the laser components or attempt to carry out maintenance on the device. The laser safety regulations could be violated. Repair of the laser module is done exclusively in our workshop. ____________________________________________________________________ aitronic...
  • Page 10: Lithium-Polymer And Lithium-Ion Accumulators

    ► If an accumulator should begin to burn don’t never extinguish with water. Pay attention to the following hints concerning the behaviour in case of fire. ____________________________________________________________________ aitronic...
  • Page 11 ► If you have some doubts concerning your extinguish tries call the fire brigade to help you. By disposal of the used batteries or accumulators, adherence to the regulations concerning battery disposal (see section Recycling Orders) should be observed. ____________________________________________________________________ aitronic...
  • Page 12: Care Instructions

    In that way sticking parts may smudge the scanner screen. In this case on one hand the scanner function will be affected, on the other hand cleaning without ignoring the above instructions isn’t possible because a solvent would be required. ____________________________________________________________________ aitronic...
  • Page 13: Repairing Screen Damages

    At this point we want to explicitly attention to that we don’t overtake guarantee for damages which are the consequence of wrong dealing with the MDE devices ____________________________________________________________________ aitronic...
  • Page 14: Communication With Pc

    Software updates in principal are possible only cable bound. All MDE devices are available with DECT module. The kind of the cable bound connection may vary depending on the type of MDE device and will be described in the further course of this chapter. ____________________________________________________________________ aitronic...
  • Page 15: Software Installation

    Directory WinDECT from the CD has to be copied to any directory of your PC. There must be unrestricted access rights for this directory. DECTOR II Directory DECTOR from the CD has to be copied to any directory of your PC. ____________________________________________________________________ aitronic...
  • Page 16: Cradle For Logiscan-600/800

    2. Switch on your computer and start MTWin respectively your user software program. 3. Put the MDE device into the docking station. 4. The MDE device now is ready for data transfer and the integrated accumulator will be charged. ____________________________________________________________________ aitronic...
  • Page 17: Docking Station For Logiscan-600/800

    4. Switch on your computer and start MTWin respectively your user software program. 5. Put the MDE device into the docking station. 6. The MDE device now is ready for data transfer and the integrated accumulator will be charged. ____________________________________________________________________ aitronic...
  • Page 18: Cradle For Logiscan-1100

    4. Switch on your computer and start MTWin respectively your user software program. 5. Put the MDE device into the docking station. 6. The MDE device now is ready for data transfer and the integrated accumulator will be charged. ____________________________________________________________________ aitronic...
  • Page 19: Wireless Dect Communication

    6. After a few seconds the MDE device should display the message „Subscription performed“. 7. This procedure has to be performed for each MDE device as the case may be. 8. Terminate DECTOR II, start the MDE devices application again with menu function and start WinDECT again. ____________________________________________________________________ aitronic...
  • Page 20: Introduction To Operation

    New input: Delete digit/character Input field will be deleted, if this isn’t empty. If input field is empty and it isn’t the first field, the whole input mask will be erased. ENTER Concludes input or activates chosen menu item ____________________________________________________________________ aitronic...
  • Page 21: Switching On/Off

    6 rows are shown to be available. It is possible to scroll this area in order to show the other available functions, e.g. menu lists with more than 5 items. Data Capturing Article No. ____________________ Quantity __________ ____________________________________________________________________ aitronic...
  • Page 22 At devices with GPS this symbol shows that GPS coordinates are available. Integrated accumulators charge state. • This symbol appears when the MDE device is in Alpha Mode. This symbol appears when the MDE device is in Overwrite Mode. ____________________________________________________________________ aitronic...
  • Page 23: Navigation In Menus And Masks

    Completing the entry in the last input field, data will be stored. Change to Focus Mode SHIFT MENU Change from Insert to Overwrite Mode and vice versa. Move backward or forward along the line of characters within the input field. ____________________________________________________________________ aitronic...
  • Page 24: Handling The Scanner

    What do the sounds mean Observe the decoding beep (default setting: short double beep). This means that the bar code has been successfully read. A longer sound (error sound) means that the chosen function respectively the chosen bar code is not permitted. ____________________________________________________________________ aitronic...
  • Page 25: Activating Barcode Scanner Or Transponder Reader

    Hold down key SCAN and direct the scanner beam to the barcode to be read. Choose the destination between MDE device and barcode in that way that the scanner beam totally covers the barcode. The MDE device responds to a successful scanning with the decoding beep and shows the scanned article number. ____________________________________________________________________ aitronic...
  • Page 26: Reading Transponder Tags

    Deleting Characters By pressing button DEL the character left to the cursor will be deleted. Deleting the Input Field By holding down the button and pressing button DEL at the same time the actual input field will be deleted. ____________________________________________________________________ aitronic...
  • Page 27: Choosing An Input Field

    ENTER is pressed in the last input field, data entry will be closed and the record will be stored into data memory. Afterwards the next empty input mask will be shown. ____________________________________________________________________ aitronic...
  • Page 28: System Functions

    Here the accumulator capacity is displayed in percent. Below a capacity of 30% the user is called upon to recharge the accumulator. At the latest, when the MDE devices signals “Battery Low! Press Enter Key“ the accumulator must be recharged. ____________________________________________________________________ aitronic...
  • Page 29: Hardware Reset

    Hardware Reset A hardware reset with the various device types will be performed as follows: • LogiScan-800: pressing keys 2, 5 and 7 at the same time. • LogiScan-600: pressing keys F1, F3 and 9 at the same time. •...
  • Page 30: System Menu

    Display the data which is stored into Flash ROM. After a data file was selected one of the following operations can be performed with this date file: Info Shows the data file information Copy Copy the data file Rename Change name of data file Delete data file ____________________________________________________________________ aitronic...
  • Page 31: System Error Message „Battery Low

    At the second notification the accumulator has left about 10% capacity. • At the third notification the accumulator has left 0% capacity. The device switches off and cannot be switched back on again. The present operation should be closed and the MDE device accumulator should be charged. ____________________________________________________________________ aitronic...
  • Page 32: Battery And Sim Card Changing

    Push the battery cover until it stops in Loosen the battery cover screw with the direction of arrow and lift off. coin or screwdriver. Lift and remove the battery on the Slide the SIM card lock down and open transparent flap. ____________________________________________________________________ aitronic...
  • Page 33 Only after completing the next charging cycle or when reaching the „Battery Low Level“ the charging control symbol shows the correct charging state of the inserted accumulator. ____________________________________________________________________ aitronic...
  • Page 34: Logiscan-600/12

    Lift and remove the battery on the open the SIM card slot. transparent plate. Insert SIM card, close the SIM card When inserting the battery its contact slot and close SIM card lock. surfaces must point to the contact pins in the battery compartment. ____________________________________________________________________ aitronic...
  • Page 35 Only after completing the next charging cycle or when reaching the „Battery Low Level“ the charging control symbol shows the correct charging state of the inserted accumulator. ____________________________________________________________________ aitronic...
  • Page 36: Software Update

    ► If M16Start shows the error message „Bad Security Key!“ menu function Security/Key Input must be selected and the key 8602 must be entered to force M16Start to start the software update. After that a hardware reset must be released. ► After the download is terminated M16START closes automatically. ____________________________________________________________________ aitronic...
  • Page 37: Error Correction - What To Do If

    Accesspoint (serial port or IP address). ► The LED „DTR“ of the concerning Accesspoint must flash. ► If these demands are met the concerning MDE device has to be registered to the Accesspoint by means of utility DECTOR II. ____________________________________________________________________ aitronic...
  • Page 38: Accessories

    Deals for data communication and charging device at the same time. Interfaces: RS-232, USB or LAN Charging time: about 2 hours Cradle for LogiScan-1100 Deals for data communication and charging device at the same time. Interfaces: RS-232, USB or LAN/WLAN Ladezeit: about 3 hours ____________________________________________________________________ aitronic...
  • Page 39: Truck Charging Station For Logiscan-600/800

    The MDE device will be locked to the charging station. Charging Time: about 2 hours Charging Station for LogiScan-600/800 Wall or table assembly Charging Time: about 2 hours Belt Holder for LogiScan-600/800 Adjoining the belt holder for the LogiScan-600 is shown, ____________________________________________________________________ aitronic...
  • Page 40: Accesspoint For Dect Rf Network

    Accessories _____________________________________________________________ Accesspoint for DECT RF Network RF Module: MD-32 Module Interfaces: RS-232, LAN Connection of up to 16 MDE devices per Accesspoint possible ____________________________________________________________________ aitronic...
  • Page 41: Recycling Orders

    Legal notice for waste disposal In accordance with the European legislation, it is forbidden to dispose of electrical and electronic equipment in the domestic waste. The aitronic GmbH takes back all of it placed on the market or sold electronic devices and accessories.
  • Page 42: Standard Application 03000

    This function can be locked with menu function Admin/Settings/Lock Shift ESC. In case of a password was set this must be entered when releasing function Shift ESC. At this the setting Admin/Settings/Lock Shift ESC wouldn’t be regarded. ____________________________________________________________________ aitronic...
  • Page 43: Menu: Options

    By selected this option a time stamp (record store time) will be added to each record when transferring the data file. Double Input When this option deselected, it isn’t possible to scan or to enter manually two identical article numbers directly one after another. ____________________________________________________________________ aitronic...
  • Page 44 If this option is selected Bluetooth deals as cable replacement and the communication with the MDE device will be done by means of MTWin. Bluetooth/Master If this option is selected the MDE device operates as a Bluetooth master, otherwise as a slave. ____________________________________________________________________ aitronic...
  • Page 45: Sub Menu: Transponder Options

    If this option isn’t selected all transponder tags were treated as read only transponder, that means that only the transponder id. will be read and stored. If this option is selected with writeable transponders the data will be read and shown in Mask 21. ____________________________________________________________________ aitronic...
  • Page 46: Menu: Admin

    Please confirm.. Not implemented! will be shown. Accu Capacity Checking the integrated accumulator capacity. Date/Time Checking and correcting date and time. Password Entering a password. This deals for protection against unauthorized access to the Options and Admin menu. ____________________________________________________________________ aitronic...
  • Page 47 Calling the GPS Test (Mask 5). Bluetooth Setup Displays the available Bluetooth devices (see chapter Bluetooth Communication on page 12-30). If the Bluetooth communication with menu Options is disabled, wird „Bluetooth not active!“ will be displayed and the function can’t be executed. ____________________________________________________________________ aitronic...
  • Page 48: Sub Menu: Keyboard Settings

    Erase Data Lock Shift ESC ----status line----- Language Keyboard Settings DECT Setup Keyboard Lock Locking the keybord. Only key ON/OFF, MENU, SCAN and ENTER are left unlocked. Lock Shift ESC Locking function Shift ESC (returning to system level). ____________________________________________________________________ aitronic...
  • Page 49: Sub Menu: Dect Setup

    Wait for Response When this option is selected the MDE device will wait for a response after having sent a record. During this waiting time „Waiting for Response…” will be displayed and further article numbers may be not entered. ____________________________________________________________________ aitronic...
  • Page 50: Gprs Setup

    The fields APN, User and Password for the specified providers can be taken from the following list by pressing F1 (possibly some times): Netz- Pass- SMS- betreiber User word Service-Center internet.eplus.de eplus +491770610000 E-Plus internet.t-d1.de t-mobile +491710760000 T-Mobile event.vodafone.de +491722270000 Vodafone ____________________________________________________________________ aitronic...
  • Page 51 1...40 digit mail address of sender Password 1...11 digit password fir Sender Mail Account. Subject 1...40 digit Subject of mail to send. Receiver 1...40 digit mail address of receiver. After having confirmed the entry with ENTER mask 1 will be displayed again. ____________________________________________________________________ aitronic...
  • Page 52 Area and are preserved also in the case of cold start or formatting the Flash ROM. A return to the previous mask is performed. The settings are not stored and a return to the previous mask is performed. ____________________________________________________________________ aitronic...
  • Page 53: Wlan Setup

    1...40 digit mail address of sender Password 1...11 digit password for sender mail account. Subject 1...40 digit subject of mail to be sent. Receiver 1...40 digit mail address of receiver. After having confirmed the entry with ENTER mask 4 will be displayed. ____________________________________________________________________ aitronic...
  • Page 54 Area and are preserved also in the case of cold start or formatting the Flash ROM. A return to the previous mask is performed. The settings are not stored and a return to the previous mask is performed. ____________________________________________________________________ aitronic...
  • Page 55: Submenü: Gps Settings

    Records which were stored without GPS coordinates are added with the actual GPS coordinates and the time stamp. This procedure will be continued until a time difference of greater than 3 minutes or a record which was stored with GPS coordinates will be found. ____________________________________________________________________ aitronic...
  • Page 56: Gps Test

    UTC: Universal Time Coordinated with dimension hhmmss.nnn Function Activating the GPS module Deactivating the GPS module Resetting the GPS module Leaving the GPS Test and showing the mask of the standard program which actually is parameterized. ____________________________________________________________________ aitronic...
  • Page 57: Menü: Info

    The application contains the required software module for the GPRS resp. WLAN Setup The application contains the required software module for Transponder R/W functionality. Without this module (in case of an integrated transponder module) only the reading of the transponder id. is supported. ____________________________________________________________________ aitronic...
  • Page 58: Loading The Gprs/Wlan Parameter Table

    • Spaces are only permitted within parameter strings (on the right side of character „=“ • Parameter names are not case sensitive • Parameters which are not referred by provided parameter names are not changed. ____________________________________________________________________ aitronic...
  • Page 59 GPRS_MailReceiver=mail-receiver<CR> GPRS_FTPServerName=ftp-server-name<CR> GPRS_FTPUserName=ftp-user-password<CR> GPRS_FTPPassword=ftp-password<CR> // GPRS_DUE_Mode: 0 - FTP, 1 - Mail, 2 - SMS GPRS_DUE_Mode=n<CR> WLAN_APN=aoa2wlan<CR> WLAN_APN_PW=wlan-password<CR> WLAN_MailServerAdr=mail-server-adresse<CR> WLAN_MailSender=mail-sender<CR> WLAN_MailSenderPW=mail-sender-password<CR> WLAN_MailSubject=mail-subject<CR> WLAN_MailReceiver=mail-receiver<CR> WLAN_FTPServerName=ftp-server-adresse<CR> WLAN_FTPUserName=ftp-user-name<CR> WLAN_FTPPassword=ftp-password<CR> // WLAN_DUE_Mode: 0 - FTP, 1 – Mail, 2 - SMS<CR> WLAN_DUE_Mode=n<CR> ____________________________________________________________________ aitronic...
  • Page 60: Barcode Capturing

    Otherwise the preset quantity can be overwritten by making a 1...10 digit manually entry. After leaving the quantity field with key ENTER or scanning the next barcode the record is stored with a time stamp. The time stamp will only be transmitted if option Time Stamp is selected. ____________________________________________________________________ aitronic...
  • Page 61: Reading/Writing Transponder

    This message must be confirmed with key ENTER and reading must be repeated. The data bytes are interpreted as follows: Byte Field Name Format 0...9 Date tt.mm.jjjj 10...11 Programming Counter tt...tt 12...23 Text The transponder id. and transponder data will be shown: ____________________________________________________________________ aitronic...
  • Page 62 ----status line----- will be shown. After confirming with key ENTER programming must be repeated. The programmed data will also be stored into the scanners data memory. Successful programming of the transponder will be shown for about 2 seconds with ____________________________________________________________________ aitronic...
  • Page 63: Displaying Records

    Once the record is displayed it can be deleted by pressing the button DEL. If the displayed record wasn’t deleted the function "Delete Record? ENTER=yes" is displayed. By pressing button ENTER the record is deleted. Each other key cancels the function. ____________________________________________________________________ aitronic...
  • Page 64: Message „Data Memory Full

    Transmission__ Data Transmission please wait... ----status line----- After a successful data transfer the data memory is deleted by MTWin and the input mask from the standard program will be displayed. The transferred records have the following data format: ____________________________________________________________________ aitronic...
  • Page 65 Degrees Minutes with decimal digits mm.mmmm GPS y coordinate (Latitude) y..y im Format ggmm.mmmm Degrees Minutes with decimal digits mm.mmmm Storing of GPS coordinates may be switched on/of by means of menu function Admin/GPS Settings/Store Coord. ____________________________________________________________________ aitronic...
  • Page 66: Dect Data Transmission

    If there is break of the data transmission Data Capturing Please confirm KSt. _______________ Art.Nr. ____________ Data Transmission Menge _____ Error! ----status line----- will be shown. After confirming the error message with key ENTER the data transmission has to be repeated. ____________________________________________________________________ aitronic...
  • Page 67 After a successful data transmission the data memory will be erased and for about 2 seconds Data Capturing Article Number Info ____________________ All Data Quantity __________ transmitted! ----status line----- will be shown. After that the entry mask of the selected standard program will be shown. ____________________________________________________________________ aitronic...
  • Page 68: Gprs Or Wlan Data Transmission

    ESC. mode Transmission Please wait ... SQ: nn% Mask 20 The transmission mode will be displayed in the title line (mode= “FTP“, “Mail“ or “SMS“). The status line shows the signal quality SQ in percent. ____________________________________________________________________ aitronic...
  • Page 69 If the data transmission was performed successfully mode Transmission SQ: nn% Mask 20 will be shown and the data memory will be erased. After pressing ESC or ENTER the entry mask of the selected standard program will be shown. ____________________________________________________________________ aitronic...
  • Page 70: Activating The Sim Card After Pin Error

    Entering PUK1 resp. PUK2 is required. An invalid entry will be replied with error message „Please confirm – Invalid PINn!“. After entering the PUK the entering of an new PIN is required. After that mask 12 will be shown and the data transmission has to be started again. ____________________________________________________________________ aitronic...
  • Page 71: Bluetooth Communication

    MDE device is connected to that. Deletes list of Bluetooth devices, searches Bluetooth devices again and displays them. Displays previous Bluetooth devices Displays next Bluetooth devices ENTER Makes a connection to displayed Bluetooth device. ____________________________________________________________________ aitronic...
  • Page 72: Deleting The Data Memory Manually

    Admin menu. Options Info Admin Password: Artikelnummer _____________ ___________________ Quantity __________ ----status line----- By entering the correct password the Admin menu is shown: Options Admin Info Accu Capacity Artikelnummer Date/Time ___________________ Password Quant Erase Data___ ----status line----- Language ____________________________________________________________________ aitronic...
  • Page 73 Info Admin Accu Capacity Artikelnummer Please confirm_ Date/Time ___________________ Erase Data? Password Quant _______ ENTER = yes Erase Data___ ----status line----- Language By confirming with button ENTER the data memory is deleted. Each other button cancels this function. ____________________________________________________________________ aitronic...
  • Page 74: Logging

    Tx Log on Quantity __________ ----status line----- Output of log information together with the data Tx Log on No output of log information (default). Tx Log off After data transmission it will be switched to „Tx Log off“. ____________________________________________________________________ aitronic...
  • Page 75 5 < Q G H I J A = b c d e f l > 0 __________________________________________________________________________ < C D E F = g h i f > 2 < D E Q R H T = j a b c d e > __________________________________________________________________________ Code 2/5 int. ÄNdz&ä 4567890 Ä!-8CNYdpä 01223344556677 ____________________________________________________________________ aitronic...
  • Page 76 Standard Application 03000 ________________________________________________ 12-35 Code 2/5 std. <01236> 0123 <1234565> 123456 __________________________________________________________________________ Code 128 ÖCode-128:ä Code-128 Öabc-ABC-123_ä abc-ABC-123 ____________________________________________________________________ aitronic...

This manual is also suitable for:

Logiscan-600Logiscan-1100

Table of Contents