Ropam elektronik NeoGSM-IP User Manual

Alarm panel with build-in automation and wifi.
Hide thumbs Also See for NeoGSM-IP:

Advertisement

NeoGSM-IP – alarm panel with build-in automation
Ropam Elektronik
Tel. +48 12 272 39 71
Faks +48 12 379 34 10
User manual.
Polanka 301
32-400 Myślenice, Polska
and WIFI.
www.ropam.com.pl
biuro@ropam.com.pl
Document version : 1.0
2018-04-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NeoGSM-IP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ropam elektronik NeoGSM-IP

  • Page 1 NeoGSM-IP – alarm panel with build-in automation and WIFI. User manual. Ropam Elektronik Tel. +48 12 272 39 71 Polanka 301 www.ropam.com.pl Document version : 1.0 32-400 Myślenice, Polska Faks +48 12 379 34 10 biuro@ropam.com.pl 2018-04-01...
  • Page 2 - according to the application. The device is a source of electromagnetic waves, so in specific configurations it can interfere with other radio devices). The Ropam Elektronik company is not responsible for the malfunctioning of the GSM network and the consequences of possible technical problems. WEEE LABELING Waste electrical and electronic equipment must not be disposed of with normal household waste.
  • Page 3: Table Of Contents

    SD, SDHC card........................18 Room thermostat........................18 Touch panel TK-3W / TK-3B......................19 Description..........................19 Numeric keyboard operations....................19 System operations........................20 Service operations........................21 RopamNeo application........................22 Remote controllers........................23 © 2018 Ropam Elektronik...
  • Page 4 DTMF control..........................36 DTMF control: arming........................ 36 DTMF control: outputs....................... 36 DTMF control: end of queue for VOICE..................37 DTMF control: door intercom bolt....................37 Version history..........................38 Information............................38 © 2018 Ropam Elektronik...
  • Page 5: General Description

    - a version in the housing for the DIN rail is also available. Appliance. The alarm system built on the basis of NeoGSM-IP series alarm panels, TPR-xx touch panel and other additional devices is an ideal solution for residential buildings and small commercial facilities.
  • Page 6: Warnings

    • intelligent lighting, Warnings. Ropam Elektronik devices are part of a full alarm system, whose effectiveness depends on the quality and technical condition of all devices (detectors, signaling devices), cabling, etc. included in the system. The user is obliged to periodically test the operation of the alarm system. It should be checked whether the control panel reacts to the violation of individual detectors (PIR, reed switches, etc.) or signaling...
  • Page 7: Requirements For Sms, Dtmf Control

    General description. Str. 03 Ropam Elektronik is not responsible for the correct operation of operators and GSM network infrastructure used for notification of alarm states and remote control. It is recommended to use a GSM operator that guarantees coverage of min. two BTSs of a given system location with GSM communication.
  • Page 8: System Operation

    TPR-xx allows for intuitive control and control of the alarm system, thanks to the interactive interface using pictograms and text prompts, navigating and using functions is simple and does not require the user to remember the function code, eg strong vigilance, blocking the sensors..Control panel has © 2018 Ropam Elektronik...
  • Page 9: Main Window

    TPR-4 touch panel allows you to place any icons anywhere on the two panel screens and some of them assign multiple actions. Icon Description Full system utilities. Possible (set in NeoGSMIPManager): - selection of zones - required code - displaying the zone selection screen © 2018 Ropam Elektronik...
  • Page 10 TPR-4 panel. Giving, changing, deleting user codes and names (up to 32). Menu of user and service settings. Blocking an input or group of inputs. Set in the NeoGSMIPManager: - entry number - group blocking of zones © 2018 Ropam Elektronik...
  • Page 11 - blocking the zone after pressing the icon (after disarming the entry system they are unblocked) - indication of the status from the PLC I / O module input Room thermostat. Possible (set in NeoGSMIPManager): - thermostat selection (No. 1 or No. 2). Controlling relay in touch panel. © 2018 Ropam Elektronik...
  • Page 12 Possible (set in NeoGSMIPManager): - number of output / outputs - requiring a code to enable Turning off output group. Possible (set in NeoGSMIPManager): - number of output / outputs - requiring a code to enable © 2018 Ropam Elektronik...
  • Page 13 Basic information about the system: Firmware of control panel, Panel firmware, Power supply to control panel and modem, Status of AP-IP module Panic Fire Single output control. Fan Single output control. Heater Single output control. Power supply © 2018 Ropam Elektronik...
  • Page 14 System operation. Str. 10 Icon Description Single output control. Sprinklers Wicket Single output control. Garden lights Single output control Plugin Single output control Left Single output control Right Single output control. Up © 2018 Ropam Elektronik...
  • Page 15: Status Bar

    (QWERTY) is reported. For selected functions an optional application without a code is available (designation: service). Window type / Keyboard Confirmation of the function Exit from function Numerical Full ENTER Graphic © 2018 Ropam Elektronik...
  • Page 16: Arming Full Armed Mode

    Warnings, depending on the system settings (service): - if the zones of the control panel are violated, a message will be displayed asking for blocking the zones: "Block violated inputs? - YES / NO", © 2018 Ropam Elektronik...
  • Page 17: Arming Night Mode

    #. If the sequence is correct, the control panel will display a zone selection window with their guard status. Select partitions (by pressing partition name) and confirm or select the all button. © 2018 Ropam Elektronik...
  • Page 18: Canceling Alarm

    During the preview, the display will show the graphic status of the zones: status + name of the zone. Status is presented through a colored semaphore, where the color means: © 2018 Ropam Elektronik...
  • Page 19: Event History

    Enter the code and confirm #. If the sequence is correct, control panel will display the event memory, line syntax with a single event:: RR.MM.DD GG.MM EVENT IN THE SYSTEM. Navigation in history is done by buttons Exit from the browse follows the button © 2018 Ropam Elektronik...
  • Page 20: Editing Codes

    ; if a code is required, a numeric keypad will be displayed, enter the code and confirm #. Blocking consists in selecting X at the selected input. Output and confirmation is done via , exit from blocking without confirmation occurs via © 2018 Ropam Elektronik...
  • Page 21: Outputs Controling

    TURNING OFF relay output in TP1 panel (service) 1212 offtp1 System address for a given touch panel is defined by the installer. When configuring a given output in monostable mode, sending the "offtpX" command shortens the time of this output. © 2018 Ropam Elektronik...
  • Page 22: Sd, Sdhc Card

    Manual change of set temperature Heater icon - active thermostat – executieve output=1 Diagram showing duration of thermostat in a given hour Selection of current profile Thermostat settings Exit (temperature profiles, weekly program) Temperature profiles Calendar © 2018 Ropam Elektronik...
  • Page 23: Touch Panel Tk-3W / Tk-3B

    Str. 19 Touch panel TK-3W / TK-3B. Description. The TK-3x touch keypad is used to control the NeoGSM-IP series alarm control panel. Due to the limited functions of the 'partition keypad', a dedicated touch panel should be installed in the system.
  • Page 24: System Operations

    LED [Alarm + Failure] Blink simultaneously (1x / 1s) = SERVICE MODE System operations. Standard system operation. (factory [CODE] for the NeoGSM-IP system is [5555]) Arming the partition (arming). [CODE][#] Disarming the partition (disarming) or canceling an alarm i partition.
  • Page 25: Service Operations

    PCB with compressed air. System should be periodically tested for proper operation and communication. If the casing or touch panel becomes dirty, clean it with the usual means for LCD computer monitors. © 2018 Ropam Elektronik...
  • Page 26: Ropamneo Application

    RopamNeo application. Str. 22 RopamNeo application. RopamNeo (Google Play / AppStore) Full manual for the RopamNeo mobile application (Android, iOS), available at: https://ropam.com.pl/en/towar/706/ropamneo.html © 2018 Ropam Elektronik...
  • Page 27: Remote Controllers

    Remote controllers. Str. 23 Remote controllers. NeoGSM-IP system can be operated by means of the TR-4 and Keyfob-Aero radio remote controls manufactured by Ropam Elektronik. Keyfob Aero. If the system has an APm-Aero or AP-Aero radio controller installed, remote control of system standby and system functions via two-way radio remote controls is available.
  • Page 28 - arming system sabotage (detectors) of 10 signals (10x 0.5s.), - Information about remote arming can be sent via SMS to selected telephone numbers. Clearing the alarm can also delete any notification action; SMS, SMS + VOICE, VOICE (service). © 2018 Ropam Elektronik...
  • Page 29: Sms Control

    SMSs controlling the outputs can have any content, eg pump on, pump off. Exact parameters of the outputs and their intended use are determined by the installer. Control syntax using factory control commands is shown below: © 2018 Ropam Elektronik...
  • Page 30: Control Of The Video Intercom

    If the system is integrated with the video intercom system (VAR-1 integration element), then an SMS command to open the rafter (gate / wicket) is available. Command Description Example #### doorlock Turning on the system of the doorbell transceiver in Kenwei 5555 doorlock doorphone (gate / gate opening) © 2018 Ropam Elektronik...
  • Page 31: Thermostatgsm: Monitoring And Changing Temperature Thresholds

    If an analog input is used in the system, it is possible to remotely change the L and H temperature thresholds via SMS. Command Description Example Comments Remote change of threshold Configuration #### aia zzzz 1111 aia 9999 a for AI input, changed © 2018 Ropam Elektronik...
  • Page 32: Control Of The Aero Wireless System

    The system status can contain (display parameters are configured in control panel): - system time (STATE state timestamp), - partition status, - GSM network status, coverage, - system version, - power supply status and DC power supply voltage, - temperature value from sensors, © 2018 Ropam Elektronik...
  • Page 33: System Status: Sms Status

    - input intact + weak battery of Aero wireless device (visibility of individual inputs is configured by the installer) Wyjścia (O): O1 ...O8 output status, 0 = output inactive, 1 = active output (logic state) (the visibility of individual outputs is configured by the installer) © 2018 Ropam Elektronik...
  • Page 34 C], (the visibility of individual sensors and their names is configured by the installer) Sensor 4 Partition 1 state of zones in the system (visibility of zones and their names is configured by the installer) Partition 4 © 2018 Ropam Elektronik...
  • Page 35: System Status: Zones Status Sms

    = command to top up a given operator using a 14-character code from "scratchcard" (zzzzzzzzzzzzzz = scratchcard): - Heyah: *109*zzzzzzzzzzzzzz# - Tak-Tak: *111*zzzzzzzzzzzzzz# - Plus GSM: *123*zzzzzzzzzzzzzz# - Orange: *125*zzzzzzzzzzzzzz# - Play: *100*zzzzzzzzzzzzzz# © 2018 Ropam Elektronik...
  • Page 36: Ussd Check Codes For Prepaid Account Status

    #### restart Control panel restart 5555 restart #### downloading x Remote activation / 5555 downloading 1 Configuration deactivation of the modem changed connection function X = 1 function included x = 0 function disabled © 2018 Ropam Elektronik...
  • Page 37: Other Sms Commands

    Removes the indicated #### = access number from the memory. code After the correct execution, nnnn = 1111 deltel +485556668 the module sends back telephone SMS "Number deleted", number otherwise "Error, no number in international removed" format © 2018 Ropam Elektronik...
  • Page 38 Change of humidity thresholds: xxxx huma x val - where x sensor number 1.2 val- Example: 5555 huma 1 80 humidity value 0-100%: xxxx huma x val - where x sensor number 1.2 val- humidity value 0-100% © 2018 Ropam Elektronik...
  • Page 39 #### heating 22 xx - value of Setting the room thermostat Where 22 is the temperature the set temperature sent to the central office. temperature. #### netstat Status of RopamNet bus #### wrltemp Information about wireless sensors (AERO) © 2018 Ropam Elektronik...
  • Page 40: Dtmf Control

    If VSR-2 is installed, a voice message Switch on Ox output, where zzzz 2221* will be played: DTMFOn code for the given "Output is attached" output "Output is turned off". in case of error: message: "error" © 2018 Ropam Elektronik...
  • Page 41: Dtmf Control: End Of Queue For Voice

    Description Example Comments rrrr* Code: yyyy = opening bolt DTMF code SWITCHING on output 1234* (service) latch to open the video It is not recommended to use a single digit, door phone. do not use #. © 2018 Ropam Elektronik...
  • Page 42: Version History

    2018-04-01 Information. The Ropam Elektronik company is the sole owner of copyrights to the materials contained in the documentation, catalog and website, in particular for photos, descriptions, translations, graphic form, presentation. Any copying of information or technical materials found in catalogs, on websites or otherwise provided by Ropam Elektronik requires written permission.

Table of Contents