Typical Wiring; Technical Data - W.E.ST. MDR-133-U Technical Documentation Manual

Pressure control module
Table of Contents

Advertisement

7.5 Typical wiring

CAUTION: The solenoid cables should be screened due to electro-magnetic emissions.
CAUTION: plugs with free-wheeling diodes and LED indicators cannot be used with current-
controlled power outputs. They interfere with the current control and can destroy the output
stage.

7.6 Technical data

Supply voltage (Ub)
Power consumption
External protection
PWM output
Max. output current
Frequency
Sample time solenoid current
control
Temperature range
Housing
Material
Flammability class
Weight
Connections
Page 37 of 42
10... 30 (incl. ripple)
[VDC]
[W]
max. 2,5 + Power of the connected coil
[A]
3 medium time lag
Wire break and short circuit monitored
[A]
2,6
60... 2941 selectable in defined steps
[Hz]
[µs]
125
-20... 60
[°C]
Snap -on module acc. EN 50022
-
PA 6.6 polyamide
-
V0 (UL94)
[kg]
0,250 (incl. standard module)
3 x 4-pole terminal blocks
MDR-133-*-2030
29.08.2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdr-133-p

Table of Contents