Typical Wiring; Connection Examples - W.E.ST. MDR-133-U Technical Documentation Manual

Pressure control module
Table of Contents

Advertisement

4.4 Typical wiring

Enable
Run
Ramp
pressure command value
(0..10V oder 4..20mA)
actual pressure value
(0..10V oder 4..20mA)

4.5 Connection examples

SPS / PLC 0... 10 V sensor- / commandsignal
+In PIN 13 or PIN 14
In PIN 12 (GND)
valves (6 + PE plug) with integrated electronics
PIN 12
PIN 15
PIN 16
Page 16 of 42
Status
Ready
1
2
5
6
9
10
0V
13
14
e.g. 24 V
e.g. 24 V
A : 24 V supply
B : 0 V supply
C : GND or enable
D : + differential input
E : - differential input
F : diagnosis signal
PE -
power supply
3
4
7
8
11
12
10 V Reference voltage
15
16
shield
0... 10V / 4... 20mA
PLC or sensor 4... 20 mA two wire type
+In PIN 13 or 14
PIN 11 (GND)
PLC or sensor 4... 20 mA three wire type
+In PIN 13 or 14
PIN 11 (GND)
MDR-133-*-2030
24V
0V
output
To power amplifier /
proportional valve.
29.08.2019