CHAPTER 6 - Options

Options

Regenerative modules

If during the deceleration phase,green OK led switch off ,we suggest to increase the external
capacitor.
When inertia load is elevated ,often external capacitor itʼs not enough and then we must
use the regeneratives modules.
Rack regenerative module
(same size of an amplifier)
Motherboard regenerative module

External series inductor

These amplifiers need inductor connected in series to the motor only if the motor has a
internal inductance lower then 0,7-0,8 mH.
So we improve form factor and the servomotor donʼt over heating.
NOTE
IN the electric box,the inductance,must be connected with short wires between amplifier
and inductance too.