Pentair Myers CGL-01SW Installation And Service Manual page 4

Advertisement

1 PHASE PUMPS
1. Use an amprobe to check the amperage of the
pump.
2. Turn the hand-off-auto switch to the "HAND"
position and compare the amperage reading to
the values shown on the chart. (See page 9).
3. If you get a reading of 0, make sure there
is voltage to the motor leads. Push the Klixon
overload reset button in the control panel. the on
winding overload may be tripped. Wait 15 minutes
and try again. If you still do not get a reading,
either the motor has failed or there might be a
wiring problem between the control panel and
pump (improper connection in the junction box).
3 PHASE PUMPS
1. Use an amprobe to check the amperage of any of
the power leads going to the pump.
2. Turn the hand-off-auto switch to the "HAND"
position and compare the amperage reading to
the values shown on the chart.
CHECKING PUMP AND FLOAT RESISTANCE
TO CHECK PUMP OR FLOAT, DISCONNECT INCOMING POWER AND REMOVE WIRES
FROM THE TERMINAL BLOCK AND WITH AN OHMMETER CHECK THE MEASUREMENTS PER CHART.
CORD
MEASURED
MEASURED
Power
Motor Winding
Cord
Power
Motor Winding
Cord
Power
Ground to Motor Winding
Cord
(Green to Red, Black or White)
Power
Ground to Seal Probe (Opt.)
Cord
(Green to Brown)
Float
Ground to Float Contacts
Cord
(Green to Black or White)
Float
Float Contacts
Cord
(Black to White)
NOTE: Readings may vary slightly depending on length of wire running to the motor and the accuracy of the measurement instrument.
23833A150 11/08/12
CHECKING PUMP CURRENT DRAW
ITEM
CORRECT
READING
(See Chart)
(1 Phase)
(See Chart)
(3 Phase)
Infinity to 200
Infinity to 200
Infinity to 200
0 - Float On
Infinity-Float Off
3. If you get a reading of 0, make sure there is
voltage to the motor leads. Push the overload
reset button on the overload relay in the control
panel. If you still do not get a reading either the
motor has failed or there might be a wiring
problem between the control panel and pump
(improper connection in the junction box).
4. If you get high amperage readings on 2 wires and
a zero reading on the third, you have a single
phase condition which could be caused by one
of the following:
A. One motor lead is not connected properly.
B. You have lost 1 phase of the 3 phase power
coming into the panel.
C. One winding in the motor is open.
OHMMETER
IF YOU GET ANY OTHER READING
SETTING
CHECK FOR THE FOLLOWING:
R x 1
R x 1
R x 100K
R x 100K
R x 100K
R x 1
4
Damaged winding or cord
Damaged winding or cord
Damaged winding or cord
moisture in motor
Water in seal chamber or
damaged cord
Water in float or damaged cord
Switch has failed or damaged cord