Temporary User Overrides
The TP5000 has several useful overrides which can be selected without
affecting the thermostat programming
Selection of time or actual room temperature in main LCD display –
press + and – together to change between settings (Fig.11)
Temporary override of programmed temperature – press ∧ ∧ ∧ ∧ ∧ or ∨ ∨ ∨ ∨ ∨ until
required temperature is displayed (override will automatically cancel at
beginning of next programmed event) (Fig.12)
Temporary use of weekend programmes – press ∧ ∧ ∧ ∧ ∧ and ∨ ∨ ∨ ∨ ∨ together
once (override cancels at 2:00am) (Fig.13)
Frost Protection – a constant low temperature can be selected whilst
away from home - press ∧ ∧ ∧ ∧ ∧ and ∨ ∨ ∨ ∨ ∨ together twice (Fig.14). To return to
automatic programming press ∧ ∧ ∧ ∧ ∧ and ∨ ∨ ∨ ∨ ∨ together again
Summer Time / Winter Time Clock
To change from Summer to Winter (clocks back) -
G
press and hold - button (Fig.15)
To change from Winter to Summer (clocks forward) -
G
press and hold + button (Fig.15)
Battery Replacement
A low battery symbol will flash in the LCD display (Fig.16)
G
You have 15 days to replace the battery before the unit will switch off.
G
When changing batteries, remove old batteries and insert new ones within
G
ONE MINUTE and programming will not be lost.
NB. If the display ever goes blank during normal operation, the batteries will
need to be renewed, the unit reset and the time and programmes reset.
Selection of time
Fig.11
or actual room
temperature
in main LCD
Temporary
Fig.12
override of
programmed
temperature
Fig.13
Temporary use
of weekend
programmes
Fig.14
Frost
Protection
Fig.15
Clocks
back
Fig.16
03 57
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
x 2
Clocks
forward
16
Danfoss Randall Ltd
Ampthill Road
Bedford, MK42 9ER
Tel: 01234 364621
Fax: 01234 219705

Advertisement

loading
Need help?

Need help?

Do you have a question about the TP5000 and is the answer not in the manual?

Questions and answers

joe considine
March 14, 2025

the tp5000 thermostat control is blank I have changed the batteries and pressed the reset nothing seems to work can you advise

1 comments:
Mr. Anderson
March 14, 2025

The Danfoss TP5000 thermostat control may remain blank after changing the batteries and resetting due to the following reasons:

1. Poor Battery Contact: The metallic strips in the battery chamber may have been pushed back too far, preventing proper contact with the batteries. Slightly adjusting these strips with a non-metallic object like a cocktail stick can help ensure a snug fit.

2. Battery Replacement Delay: If new batteries are not inserted within one minute of removing the old ones, the unit may lose its programming and require resetting.

3. Reset Required: After installing new batteries, pressing and releasing the reset button is necessary to start the unit.

If these steps do not resolve the issue, further troubleshooting may be needed.