At+Conmin Query And Set Minimum Connection Interval Command; At+Conmax Query And Set Maximum Connection Interval; At+Conto Query And Set Connection Timeout Command; At+Discon Disconnection Conmand - Ebyte CC2541 User Manual

2.4ghz ble 4.0
Table of Contents

Advertisement

Ebyte Electronic Technology Co., Ltd

5.2.17 AT+CONMIN Query and Set Minimum connection interval command

Query: AT+CONMIN?
S et: AT+CONMIN=[para]
Note: Valid when next connection, power off preservation
The maximum connection interval must be no less than the minimum connection interval
5.2.18 AT+CONMAX Query and Set M
Query: AT+CONMAX?
S et: AT+CONMAX=[para]
Note: Valid when next connection, power off preservation
The maximum connection interval must be no less than the minimum connection interval

5.2.19 AT+CONTO Query and Set Connection timeout command

Query: AT+CONTO?
S et: AT+CONTO=[para]
Note: Valid when next connection, power off not preservation

5.2.20 AT+DISCON Disconnection conmand

Query: AT+DIS CON
Note: Valid immediately

5.2.21 AT+CONSTA Query Connection Status Command

Query: AT+CONS TA?
Copyright ©2012–2019,Ebyte Electronic Technology Co., Ltd
16
Command
Command
Command
Command
Command
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
aximum connection interval
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Response
+OK
Response
+OK=[para]
E104-BT01 Usermanual
Parameter
Para: ASCII
Range: 6~3200
E.g.: 8
8*1.25ms=10ms
Parameter
Para:ASCII
Range: 6~3200
E.g.: 8
8*1.25ms=10ms
Parameter
Para: ASCII
Range: 100~3200
E.g.: 500
500*10ms=5s
Parameter
None
Parameter
Para:
Connected: Connection established

Advertisement

Table of Contents
loading

Table of Contents