5.2.2 AT+RESET reset command
AT+RES ET
Note: Valid immediately
5.2.3 AT+RESTORE Factory reset command
AT+RES TORE
Note: Valid after reset
5.2.4 AT+BAUD Query and set the serial port baud rate command
Query: AT+BAUD?
S et: AT+BAUD=[para]
Note: Valid after reset
5.2.5 AT+STOPB Query and Set Serial Port Stop Bit command
Query: AT+S TOPB?
S et: AT+S TOPB=[para]
Note: Valid after reset, power off preservation
5.2.6 AT+ROLE Query and Set Bluetooth Role command
Query: AT+ROLE?
S et: AT+ROLE=[para]
Note: Valid after reset, power off preservation
Copyright ©2012–2019,Ebyte Electronic Technology Co., Ltd
13
Command
+OK
Command
+OK
Command
Command
Command
Response
Response
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Response
+OK=[para]
+OK: S ucceed
+ERR=[NUM]: Error
E104-BT01 Usermanual
Parameter
None
Parameter
None
Parameter
Para:0~4 ASCII
0=9600
1=19200
2=38400
3=57600
4=115200
Parameter
Para: 0,1 ASCII
0: 1 stop bit
1: 2 stop bit
Parameter
Para:0、1、2 ASCII
0: M aster
1: Slave
2: Observer