10. Rotate the AMS knob until the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
VC
Specification A = B
11. Press the @/1 button, and save the adjustment results in the
non-volatile memory. ("EFB =
a moment.)
Next "EF MO ADJUS (C07)" is displayed. The disc stops ro-
tating automatically.
12. Press the x/Z "PGM" button and remove the disc.
13. Load the check disc (MD) TDYS-1.
14. Roteto AMS knob and display "EF CD ADJUS" (C08).
15. Press the @/1 button and display "EFB =
imposed automatically.
16. Rotate the AMS knob so that the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
VC
Specification A = B
17. Press the @/1 button, display "EFB =
ment and save the adjustment results in the non-volatile memory.
Next "EF CD ADJUST" (C08) will be displayed.
18. Press the x/Z "PGM" button and remove the check disc
(MD) TDYS-1.
Note 1 : MO reading data will be erased during if a recorded disc is
used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
BD board
CN105 pin 4 (TE)
CN105 pin 6 (VC)
32
SAVE" will be displayed for
CD". Servo is
SAVE" for a mo-
Oscilloscope
330 kΩ
10pF
5-13. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load a test disk (MDW-74/GA-1).
2. Rotate the AMS knob and display "CPLAY1MODE" (C34).
3. Press the @/1 button and display "CPLAY1 MID".
4. Press the x/Z button when "C =
played.
5. Rotate the AMS knob and display "FBIAS ADJUST" (C09).
6. Press the @/1 button and display "
A
The first four digits indicate the C error rate, the two digits after
[/] indicate ADER, and the 2 digits after [a =] indicate the focus
bias value.
B
7. Rotate the AMS knob in the clockwise direction and find the
focus bias value at which the C error rate becomes 200 (Refer to
Note 2).
8. Press the @/1 button and display "
9. Rotate the AMS knob in the counterclockwise direction and
find the focus bias value at which the C error rate becomes 200.
10. Press the @/1 button and display "
11. Check that the C error rate is below 20 and ADER is 00. Then
press the @/1 button.
12. If the "( " in "
button.
If below 20, press the x/Z
adjustment from step 2.
13. Press the x/Z "PGM" button to remove the test disc.
Note 1 : The relation between the C error and focus bias is as
shown in the following figure. Find points a and b in the
following figure using the above adjustment. The focal
point position c is automatically calculated from points a
and b.
Note 2 : As the C error rate changes, perform the adjustment using
the average vale.
A
C error
B
200
b
AD =
/
a =
/
b =
/
c =
( " is above 20, press the @/1
-
-
button and repeat the
c
a
Focus bias value
(F. BIAS)
)" is dis-
T)".
T".
T)".