WIRING DIAGRAM

PLFY-P20VCM-E.TH
PLFY-P20VCM-E
.TH PLFY-P25VCM-E
1
[LEGEND]
SYMBOL
NAME
INDOOR CONTROLLER BOARD
I.B
CN32
CONNECTOR
REMOTE SWITCH
CN41
HA TERMINAL-A
CN51
CENTRALLY CONTROL
CN52
REMOTE INDICATION
FUSE
FUSE (6.3A/250V)
SW1
SWITCH
MODE SELECTION
SW2
CAPACITY CODE
SW3
MODE SELECTION
SW4
MODEL SELECTION
SW11
ADDRESS SETTING 1ST DIGIT
SW12
ADDRESS SETTING 2ND DIGIT
SW14
CONNECTION No.
X1
AUX. RELAY
DRAIN PUMP/DEW PREVENTION HEATER
X4
FAN MOTOR (LL)
X5
FAN MOTOR (Lo)
X6
FAN MOTOR (Hi)
X7
FAN MOTOR (Me)
ZNR
VARISTOR
C1
I.B
GRILLE
H2
9
8
10
YLW
5
5
MV
4
RED
7
ORN
5
MV
6
5
YLW
3
WHT
5
MV
2
BLU
1
5
MV
LED on indoor controller board for service
Mark
Meaning
LED1
Main power supply
Power supply for
LED2
MA-Remote controller
Notes:
1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2.In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3.In case of using M-NET, please connect to TB5. (Transmisson line is non-polar.)
4.Symbol[S] of TB5 is the shield wire connection.
5.Symbols used in wiring diagram above are,
6.The setting of the SW2 dip switches differs in the capacity for the detail, refer to the fig:w1.
PLFY-P25VCM-E.TH
1
MF
ORN
RED
WHT
1
3
5 7 9
1
(FAN)
FAN
X6
X5
X4
X7
ZNR
X6 X5 X4
X7
WHT
WHT
(CENTRALLY
HA
CONTROL)
SW1
CN41
CN51
0N
4
3
2
1
5 4 3 2 1
0FF
1 2 3 4 5 6 7 8 9 10
GRN
(REMOTE
SW2
SW3
SW4
INDICATION)
0N
CN52
0N
0FF
0FF
5
4
3
2
2 1
4 3
6 5
1
3 2
5 4
7 6
9 8
10
1 2 3 4 5
See fig:W1
Function
Main power supply(Indoor unit:220-240V)
power on
Lamp is lit.
Power supply for MA-Remote controller
on
Lamp is lit.
: terminal block,
PLFY-P32VCM-E.TH
.TH
PLFY-P32VCM-E
SYMBOL
NAME
CAPACITOR (FAN MOTOR)
C1
DRAIN PUMP
DP
DS
DRAIN SENSOR
H2
DEW PREVENTION HEATER
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR (WITH THERMAL FUSE)
VANE MOTOR
MV
POWER SUPPLY
TB2
TERMINAL
BLOCK
TRANSMISSION
TB5
MA-REMOTE CONTROLLER
TB15
THERMISTOR ROOM TEMPERATURE DETECTION
TH21
(0:/15T 25:/5.4T)
PIPE TEMPERATURE DETECTION/LIQUID
TH22
(0:/15T 25:/5.4T)
TH23
PIPE TEMPERATURE DETECTION/GAS
(0:/15T 25:/5.4T)
P.B
INDOOR POWER BOARD
DP
1
3
ORN
RED
BLU
3
1 3
1 3
(D·HEATER)
(D·U·M)
(POWER)
CND
CNC
CNP
FUSE
X1
X1
WHT
(LEV)
CN60
6 5 4 3 2 1
GRN
SW14
SW12
(VANE)
0
0
O
CN6V
1
6 5 4 3 2 1
3RD
2ND
CONNECTION
DIGIT
DIGIT
No.
6
5
LEV
: connecter.
13
PLFY-P40VCM-E.TH
.TH PLFY-P40VCM-E
1
TB2
L
RED
N
BLU
GRN/YLW
P.B
AC220-240V
DC13.1V
TRANS
CNSK(RED)
CN2S(WHT)
3
2
2
1
1
RED
BLK
3
1
(POWER
BORD)
WHT
CNDK
LED1
WHT
(DRAIN)
CN31
3
2
1
LED2
RED
WHT
BLK
SW11
(INTAKE)
(GAS)
(LIQUID)
0
CN20
CN21
CN29
2
1
2 1
2 1
1ST
DIGIT
TH23
DS
TH21
TH22
<fig:W1>
MODELS
P20
OFF
P25
OFF
P32
OFF
P40
OFF
.TH
1
TO NEXT INDOOR UNIT
PULL BOX
FUSE(15A)
BREAKER
(15A)
POWER SUPPLY
~/N 220-240V
50Hz
TO OUTDOOR UNIT
BC CONTROLLER
TB5
M1
M-NET REMOTE
M2
CONTROLLER
S(SHIELD)
DC24-30V
TB15
1
TO MA-REMOTE
2
CONTROLLER
DC8.7-13V
SW2
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6