,and is easy to remove for maintenance. > OBBLIGATORY ACCESSORIES Galletti S.p.A. hereby declares, under its sole responsibility, that 3 ways valves with hydraulic kit for 2 pipes and/or 4 pipes systems. The CSW water cassette series have been designed, built and tested in...
RATED TECHNICAL DATA Fan speed Total cooling capacity High 2,88 3,83 4,85 6,50 7,45 8,84 Sensible cooling capacity 2,38 3,11 3,90 5,15 6,11 6,97 Water flow 1115 1278 1517 Water pressure drop Heating capacity High 6,99 9,07 10,82 13,20 15,86 17,04 Water flow 1158...
COOLING CAPACITY CSW WATER CASSETTE WITH 1 HEAT EXCHANGER Inlet air temperature dry bulb Inlet air temperature wet bulb Inlet water temperature Outlet water temperature Fan speed: high medium Total cooling capacity Sensible cooling capacity Water flow rate Pressure drop on water side / Tbu 25°C / 18°C (51%) / Tw...
Page 5
COOLING CAPACITY CSW DF WATER CASSETTE WITH 2 HEAT EXCHANGERS Inlet air temperature dry bulb Inlet air temperature wet bulb Inlet water temperature Outlet water temperature Fan speed: high medium Total cooling capacity Sensible cooling capacity Water flow rate Dpw Pressure drop on water side / Tbu 25°C / 18°C (51%) / Tw...
HEATING CAPACITY MODELS WITH 1 HEAT EXCHANGER Inlet air temperature dry bulb Inlet water temperature Outlet water temperature Fan speed: high medium Heating capacity Water flow rate Dpw Pressure drop on water side 20°C / Tw 45 / 40°C 50°C / 40°C 60°C / 50°C 70°C / 60°C CSW 136...
Page 7
HEATING CAPACITY MODELS WITH 2 HEAT EXCHANGERS Inlet air temperature dry bulb Inlet water temperature Outlet water temperature Fan speed: high medium Heating capacity Water flow rate Dpw Pressure drop on water side 20°C / Tw 45 / 40°C 50°C / 40°C 50°C / 50°C 70°C / 60°C CSW 136DF...
WIRING DIAGRAMS The control panel can be reached by opening the grille and removing the metal covers as shown in the picture below. CSW 136-186-246 CSW 249-369-489 CSWDF 249 - 489 CSWDF 136 - 246 For each unit provide a mains circuit breaker (IL), with opening The following abbreviations are used in the wiring diagrams: contacts separated by at least 3 mm and an adequate protection fuse (F).
Page 13
WIRING DIAGRAMS CSW 136 - 186 - 246 CSWDF 136 - 246 CSW 249 - 369 - 489 CSWDF 249 - 489 WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...
Page 14
WIRING DIAGRAMS 230/1/50 MICROPRO-D 230/1/50 CSWDF MICROPRO-D WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...
Page 15
WIRING DIAGRAMS WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...
Page 16
WIRING DIAGRAMS WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...
Page 17
ACCESSORIES MICROPROD - Microprocessor control (in built SW - Water temperature electronic probe for or wall mounted), automatic control of the MICROPROD fan coil and valves. Water probe for the MICROPROD control panels: Microprocessor control panel for wall installation automatic selection of the cooling/heating operation complete with fan speed selector, electronic mode.
Page 18
WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...
Page 19
WC66000067-REV.00 All copying, even partial, of this manual is strictly forbidden...