FASANI BOLTED BONNET CHECK VALVES
INSTALLATION AND MAINTENANCE INSTRUCTIONS
Bolted Bonnet Check Valves, Swing Check, Lift Check,
Tilting Disc Configuration, Flanged or Welded Ends
VALVE STORAGE
Preparation and preservation for sShipment
All valves are properly packed in order to protect
the parts that are subject to deterioration during
transportation and storage on site. In particular,
the following precautions should be taken:
1. The valves must be packed with the disc in
the closed position.
1a. Flanged sealing valves: The flange
sealing surfaces (raised faces) of the
valves shall be protected with suitable
protective grease. The end faces of the
valve must be protected with plastic or
wooden discs fixed with straps.
1b. Buttweld end valves: The weld ends
surface shall be protected with suitable
protective like Deoxaluminite. The end
shall be closed with plywood or plastic
disc fixed at the edge by straps.
2. The type of packing must be defined in the
Customer's Order and shall be appropriate
to ensure safe transportation to final
destination and eventual conservation
before installation.
Emerson.com/FinalControl
Handling requirements
A - Packed valves
Crates: Lifting and handling of the packed
valves in crates will be carried out by a fork lift
truck, by means of the appropriate fork hitches.
Cases: The lifting of packed valves in cases
should be carried out in the lifting points
and at the center of gravity position which
have been marked. The transportation of all
packed material must be carried out safely and
following the local safety regulations.
B - Unpacked valves
1. The lifting and the handling of these valves
has to be carried out by using appropriate
means and at respecting the carrying limits.
The handling must be carried out on pallets,
protecting the machined surfaces to avoid
any damage.
2. With valves of large dimensions, the sling
and the hooking of the load must be carried
out using the appropriate tools (brackets,
hook, fasteners, ropes) and load balancing
tools in order to prevent them from falling
or moving during the lifting and handling.
© 2017 Emerson. All Rights Reserved
VCIOM-01614-EN 17/06

Advertisement

loading

Summary of Contents for Emerson FASANI

  • Page 1 FASANI BOLTED BONNET CHECK VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Bolted Bonnet Check Valves, Swing Check, Lift Check, Tilting Disc Configuration, Flanged or Welded Ends VALVE STORAGE Handling requirements A - Packed valves Preparation and preservation for sShipment Crates: Lifting and handling of the packed...
  • Page 2: Installation

    FASANI BOLTED BONNET CHECK VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGURE 1 Valve slinging Storage and preservation before installation INSTALLATION In case the valves have to be stored before Preparation before installation installation, the storage has to be carried out in a controlled way, and has to be performed in 1.
  • Page 3 (not for piston check). cleaning of the lines to eliminate dirt and any For a correct operation, Fasani recommends foreign objects that could seriously jeopardize that the valve shall be installed and oriented the tightness between seat/disc and the correct following the indications of figure 2.
  • Page 4: Troubleshooting Guide

    FASANI BOLTED BONNET CHECK VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS TABLE 1 - BOLT TORQUE FIGURES FOR BODY-BONNET FLANGED CONNECTIONS (Corresponding to approx. 40% of yield strength on dry steel surfaces) Materials: A193 B7 / A193 B16 / A320 L7 Material: A193 B8...
  • Page 5: Maintenance

    Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fasani is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co.