Page 2
Intended use Hidden video cameras detector "ARCANE" – further by the text the device is designed for remote detection and localization of powered hidden video cameras which are installed outside, indoors, concealed as objects or body-worn. ARCANE is able to detect both analogue and digital cameras regardless of concealment and video transmission methods.
Page 3
Technical specifications When operating with the device it is not allowed of any mechanical influences and work at low negative temperature of environment. Receiver sensitivity -148 dBm Dynamic range 80 dB Detection time (average) Analysis time (average) 10 s Continuous operating time 3 hrs Battery full recharge time not more than 3,5 hrs...
Page 4
Working with ARCANE device "ARCANE" has two main operating modes: mode of signal search and the mode of finding (localizing) the sources of signals detected by the device. 1. Turn on the device by pressing and holding the on/off button located on the right side. As soon as you see the loading screen-release the button (the firmware version is displayed at the bottom of the loading screen).
Page 5
«Info» – Will activate the localization mode, which is used to localize the source of the signal by level. Localization mode of detected signals source This mode can be accessed by choosing the «Info» option on a selected "cell". The screen will display graphs of received signal level, the number and color of which varies, depending on the signal level...
Page 6
as non-suspicious will greatly increase the efficiency and speed of your ARCANE during further search sessions. Please note that «white list» will be erased from ARCANE's memory upon turning it off (if you want to keep the white listed cells add them to permanent memory). IMPORTANT TO KNOW! In order to keep information about the "non-dangerous signal"...
Page 7
Whenever you plug in the USB power supply to the device, it will automatically turn off and enter the charging mode. IMPORTANT! Never charge ARCANE with antenna still attached to it - this may result in serious Electro Static damage to pre-amplifier circuit. Hard reset.
Need help?