Philips GreenPower LED Series Application Manual page 5

Hide thumbs Also See for GreenPower LED Series:
Table of Contents

Advertisement

Important
Influencing factors of light output
As ambient temperature increases, both the photon flux and the photon flux maintenance will decrease.
Pollution or damage of optics will also impact the light output.
Thermal protection
The GreenPower LED production module has a built-in thermal protection device. If the temperature of the module
exceeds 50 °C / 122 °F the module will blink a few times and then shut off. After cooling down the module will switch
on again automatically.
Photobiological hazard
Photobiological safety of lamps and lamp systems (EN 62471).
This International Standard describes the photobiological safety of lamps and lamp systems including luminaires.
The rating of the GreenPower LED production module according to this standard can be found in the technical
specifications.
Light source not replaceable
The light source of this fixture is not replaceable. When the light source reaches its end-of-life, the whole fixture
needs to be replaced.
Cable not replaceable
The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged, the luminaire shall be
destroyed.
Not for outdoor use
Modules are not suited to outdoor use (UV effects on material, discoloring).
September 2018
Risk Group 2:
Do not stare at the operating light source.
The philosophical basis for this classification is
that the lamp does not pose a hazard due to
the aversion response to very bright light sources
or due to the thermal discomfort.
Caution: Possibly hazardous optical
radiation emitted from this product.
Do not stare at operating lamp.
May be harmful to the eye.
Application Guide - Philips GreenPower LED production module
5

Advertisement

Table of Contents
loading