Product Information; Dimensions; Technical Specifications - Philips GreenPower LED Series Application Manual

Hide thumbs Also See for GreenPower LED Series:
Table of Contents

Advertisement

Product information

Dimensions

W1
Product name
GP LED production module 120
GP LED production module 150

Technical specifications

Type
PM 120
DR/B 120 LB HO
DR/B/FR 120 LB HO
DR/B/FR_2 120 MB HO
DR/W 120 LB HO
DR/W/FR 120 LB HO
DR/W 120 LB LO
PM 150
DR/B 150 LB HO
DR/B/FR 150 LB HO
DR/W 150 LB HO
DR/W/FR 150 LB HO
DR/W 150 LB LO
DR/W 150 LB
FR 150
Specifications
Optical
Rated average lifetime
1,4
Electrical
Input voltage
Power factor
Inrush current
Environment
Ambient storage temperature
Ambient operating temperature
Max. case temperature
1
Cooling
Relative humidity
Ingress protection rating
UL/CSA rating
September 2018
L1
D2 (Ø)
Product dimensions (mm/inch)
L1
L2
L3
1213 / 47.76
700 / 27.5
64 / 2.52
1513 / 59.57
700 / 27.5
64 / 2.52
Photon flux
Efficacy typical
1
(μmol/s)
(μmol/J)
66
3.0
66
3.0
64
2.7
66
2.6
66
2.6
25
2.5
83
3.0
83
3.0
83
2.6
83
2.6
31.5
2.5
62.5
2.6
62.5
2.1
Details
35.000 hrs, L90B50 (90% flux maintenance)
120 - 277 V AC, 50-60 Hz
> 0,9 (> 0,8 for LO versions @ 277 V)
3.0 A - 0.8 ms 120 V
5.5 A - 0.8 ms 230V
7.0 A - 0.8 ms 277V
-20 to 85 °C / -4 to 185 °F (T
)
storage
0 to 40 °C / 40 to 104 °F (T
)
operating
40 °C / 104 °F (T
)
case
Passively air-cooled
5-95% RH, no condensation allowed during storage,
operation and application
IP66
Dry, damp and wet locations
L2
D1 (Ø)
L3
EU
D1 Ø
D2 Ø
19 / 0.75
8.7 / 0.34
19 / 0.75
8.7 / 0.34
Photobiological hazard
Power
Radiation
consumption
hazard
(W)
Retinal Blue
22
Risk Group 2
22
Risk Group 2
24
Risk Group 2
25
Risk Group 2
25
Risk Group 2
10
Exempt group
28
Risk Group 2
28
Risk Group 2
32
Risk Group 2
32
Risk Group 2
12.5
Exempt group
24
Risk Group 2
30
Exempt group
Legend:
GP = GreenPower
PM = Production Module
DR = Deep Red
B
= Blue
W = White
FR = Far Red
LB = Low Blue
HO = High Output
LO = Low Output
1
Efficacy typical / Rated average lifetime / Max. case temperature
@ T
ambient
For more information about photobiological hazard see page 5
2
The luminaire should be positioned at minimum viewing distance,
3
so that prolonged staring into the light source is not expected.
All measured lifetimes are industry standard measurements
4
indicating average length of operation and not a performance
claim specific to any individual product.
Application Guide - Philips GreenPower LED production module
10 / 0.39
32 / 1.26
NAM
D2 Ø
W1
H1
7.6 / 0.3
40.5 / 1.59
40.2 / 1.58
7.6 / 0.3
40.5 / 1.59
40.2 / 1.58
2
Minimum viewing distance
3
(m)
(inch)
0.35
14
0.35
14
0.8
32
0.5
20
0.5
20
N/A
N/A
0.35
14
0.35
14
0.5
20
0.5
20
N/A
N/A
0.3
12
N/A
N/A
= 25 °C / 77 °F
40 / 1.57
Product
weight
(kg/lbs)
1.4 / 3.1
1.7 / 3.7
All other radiation
hazards
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
Exempt group
4