11. If the chemical container is empty, it can be rinsed by using the Bag
& Bottle Rinse (optional). Fit the bag bracket and place the powder
bag over the multi-hole nozzle and press the lever (B) (Fig. 19).
WARNING: Do not press lever (B) (Fig. 19) unless the multi-hole
nozzle is covered by a container to avoid spray liquid
hitting the operator.
IMPORTANT: If the bottom black manifold valve is turned to MAIN
TANK, the Bag & Bottle Rinse uses diluted spray solution from the
main tank to rinse containers of concentrated chemicals. Always
rinse the chemical containers with clean water several times until
they are clean before disposal. Turn the bottom black manifold valve
to FLUSH TANK (optional) to use clean water to rinse the chemical
containers.
12. Close valve (C) (Fig. 19) when the hopper is rinsed.
IMPORTANT: If the bottom black manifold valve is turned to MAIN
TANK, the hopper uses diluted spray solution from the main tank
to rinse the hopper of concentrated chemicals. Always rinse the
hopper with clean water when fi nished spraying. Turn the bottom
black manifold valve to FLUSH TANK (optional) to use clean water
to rinse the chemical containers.
13. Close valve (A) (Fig. 19) and the chemical hopper lid. Turn the
bottom black manifold valve back to MAIN TANK (if fl ush tank was
used). Finish fi lling main tank with clean water to desired amount.
When the spray liquid is well mixed, it may be sprayed on the crop.
Leave the agitation valve at maximum agitation so the spray liquid
is continuously ag itated while spraying.
®