Page 1
QTech. Aristospray QT190 Airless Sprayer. UK & Europe 2b Stephenstown Industrial Park Balbriggan County Dublin Ireland Australia 27 Tatura Avenue Gosford NSW 2250 Email sales@aristospray.com www.Aristospray.com www.SprayForthedecorator.com Phone UK 01895 276751 Ireland 01 690 3162 Australia 1300 229 757 International +353 1690 3162...
Page 2
Check plug & cable for loose connections and/or damage Pump does Digital display Check for error codes, if any showing contact a not cycle QTech dealer or technician for advice Pump won’t Prime valve Make sure it’s in the prime position prime Air in paint...
Page 3
TriTech T360 airless spray gun On/off switch TriTech Contractor 517 airless tip & guard 1/4” x 7.5m textile braided hose assembly PRODUCT CODES 110 volt QT190-110 240 volt QT190-220 Suction filter QTech QT190 Airless Sprayer Brought to you by Aristospray...
Damaged or entangled cords increase the risk of electric shock. When operating an airless sprayer outdoors, use an outdoor extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. QTech QT190 Airless Sprayer Brought to you by Aristospray...
Never use halogenated hydrocarbon solvents in this machine. Contact with aluminum parts may cause an explosion. Some of the most common of these solvents are: Carbontetrachloride Chlorobenzene Dichloroethane Dichloroethyl Ether Ethylbromide Ethylchloride Tethrachloethane QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 6
+ NEVER wipe off build up around the spray tip. ALWAYS wear a spray mask, gloves and protective eye wear while spraying. ALWAYS ensure fire extinguishing equipment is readily available and properly maintained. QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 7
5 Do not smoke in spraying/cleaning area. NEVER use cleaning solvents with flash points below 60°C/140°F. Some of these are: acetone, benzene, ether, gasoline, naphtha. Consult your supplier if in doubt. QTech QT190 Airless Sprayer Brought to you by Aristospray...
Allow the unit to operate until clean solvent comes from the gun. 7 Release the trigger and engage the gun safety latch. 8 Whenever you shut off the sprayer, follow the PRESSURE RELIEF PROCEDURE. QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 9
While spraying, hold the gun perpendicular, about 25-30cm (10-12 inches) away from the surface. Spray back and forth. Trigger the gun before moving and release the trigger after each stroke. Overlap by 50%. QTech QT190 Airless Sprayer Brought to you by Aristospray...
If when using maximum capacity tip size the pump cannot keep up, then you know that the tip is worn beyond capacity. QTech QT190 Airless Sprayer Brought to you by Aristospray...
7 Thread the packing nut loosely. Push the piston up through the pump fluid section. Tighten the packing nut until resistance from the disc springs is felt. Tighten a further 3/4 turn but be careful. Do not over tighten. QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 12
* Included in Packing Kit 12-002 QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 13
MOTOR HOUSING-LEFT 12-190-094 TUBE HOLDER Ø11 x Ø22 12-190-033 SCREW M4 x 35 12-001 PACKING NUT TOMMY BAR 12-190-034 SCREW M4 x 30 61475EETD HIGH PRESSURE HOSE 1/4” x 7.5M 3300 PSI QTech QT190 Airless Sprayer Brought to you by Aristospray...
Page 14
QTech QT190 Airless Sprayer Brought to you by Aristospray...
Need help?
Do you have a question about the QT190 and is the answer not in the manual?