Hubner UO-EM-EGS41 Operating And Assembly Instructions Manual

Hubner UO-EM-EGS41 Operating And Assembly Instructions Manual

Electronic function module, evaluation to u-one - electronic overspeed switch.
Hide thumbs Also See for UO-EM-EGS41:

Advertisement

Quick Links

English
Operating and Assembly Instructions
Electronic function module UO-EM-
EGS41
®
Evaluation to U-ONE
- electronic overspeed switch
certificated according EN 61508 SIL2 and DIN EN ISO 13849-1 PL d
Translation of the original
operating and assembly instructions
October 2018
ID 74481

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UO-EM-EGS41 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hubner UO-EM-EGS41

  • Page 1 English Operating and Assembly Instructions Electronic function module UO-EM- EGS41 ® Evaluation to U-ONE - electronic overspeed switch certificated according EN 61508 SIL2 and DIN EN ISO 13849-1 PL d Translation of the original operating and assembly instructions October 2018 ID 74481...
  • Page 2 ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Read the Operating and Assembly Instructions prior to assembly, starting installation and handling! Keep for future reference!
  • Page 3 ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Trademark U-ONE is a registered trademark of Johannes Hubner Fabrik elektrischer Maschinen GmbH. ® Windows is a registered trademark of Microsoft Corporation in the United States and other countries. ® Viton is a registered trademark by Du Pont.
  • Page 4: Table Of Contents

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Directory 1 General ..........................5 Information about the operating and assembly instructions ............5 Scope of supply .......................... 5 Explanation of symbols ....................... 5 Disclaimer ........................... 6 Copyright............................. 6 Guarantee terms ......................... 6 Customer service ........................
  • Page 5: General

    For other, non SIL certified electronic function modules please refer to the separate Operating and Installation Instructions. Scope of supply The scope of supply of the electronic function module overspeed switch UO-EM-EGS41 includes the Operating and Installation Instructions (with SIL safety instructions), the programming software EGS41Pro (on CD) and the programming cable.
  • Page 6: Disclaimer

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Disclaimer All information and instructions in these operating and assembly instructions have been provided un- der due consideration of applicable guidelines, as well as our many years of experience. The manufacturer assumes no liability for damages due to: ...
  • Page 7: Personnel

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Personnel Qualified personnel only are permitted to install, mount, program, commission, operate, maintain and take out of service the devices. Qualified personnel are people who have received  training to qualify as an electrician or ...
  • Page 8: Technical Data

    3.2 Short description The U-ONE universal encoder system including the basic device UOM(H) 41L-1212 and the electronic function modules UO-EM-D41 and UO-EM-EGS41 is an overspeed switch (certified to EN 61508 SIL2 and EN 13849-1 PLd). The function module is configured using a PC running a Windows® operating system (XP, Vista and 7) in conjunction with the programming software EGS41Pro included in the scope of supply.
  • Page 9: Reset Input

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 The device is equipped with a safety relay with positively driven contacts for each switching output. That facilitates 2-channel evaluation of the switching status with line monitoring by a downstream control.
  • Page 10: Type Plate /Connection Diagram

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 3.6 Type plate /connection diagram 3.7 Connected loads environment Description Worth Supply via bus connections (12 … 30 V DC) Supply voltage Power consumption max. 2 W Connection COMBICON®-terminal strips Relays with forcibly guided contacts Switching outputs S1/2 max.
  • Page 11: Connectors And Indicators

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 3.8 Connectors and Indicators Indicators S1, S2, Diag LEDs light up when switches are closed Green LED Lit: Operational Flashes 1x Absolute signal State not detected (FOC 2) Flashes 2x Speed signal...
  • Page 12: Functional Safety

    Electronic function module UO-EM-EGS41 4 Functional safety 4.1 Characteristic safety values The details below refer to the overall system consisting of: Electronic function module UO-EM-EGS41 (overspeed switch) Characteristic safety values  SIL2 to EN 61508  Performance level 'd' to EN ISO 13849-1 Safety class / standard ...
  • Page 13: Timing

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 4.2 Timing Chapter 7.4.3.2.5 of EN 61508-2 should also be taken into consideration with regard to the process safety time of the ap- plication.  Power-on time T After the power supply is turned on initial internal diagnostic checks are carried out before the device is ready for operations.
  • Page 14: Proper Use

    The universal encoder system from the series UOM 41L-1212 which includes the electronic function modules UO-EM-D41 and UO-EM-EGS41 has been designed and built solely for the intended purpose described in these Operating and Installation Instructions. It is designed to detect overspeeds (programmable), for example in electric and mechanical drives, lifting equipment and winding plant.
  • Page 15: Faults Table

    Finally, reset the fault. Please refer to the error table for a list of individual errors (Chapter 4.10) Contact Hubner-Service (page 2) if none of the actions listed above provide a solution! 4.11 Error table Error category: Error:...
  • Page 16: Transport, Packaging And Storage

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 5 Transport, packaging and storage Safety information concerning transport CAUTION! Material damage caused by improper transport! Observe the symbols and information on the packaging:  Do not throw - risk of breakage ...
  • Page 17: Returning Devices (Repairs/Goodwill/Warranty)

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 Returning devices (repairs/goodwill/warranty) Devices that have come into contact with radioactive radiation or radioactive materials are not taken back. Decontaminate devices that have may come into contact with harmful chemical or biological substances before returning.
  • Page 18: Certificate

    ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41 6 Certificate...
  • Page 19 ® Universal encoder system U-ONE Electronic function module UO-EM-EGS41...

Table of Contents