  • Page 1 CX6162/66 Clex prime Compact electronic knob cylinder Operating and assembly manual...
  • Page 2: Version:

    CX6162/66 ABLE OF CONTENTS Imprint Operating and assembly manual (English) Electronic knob cylinder CX6162/66 Document number: 0B77 Version: 1.02 Status: 11.05.2018 Manufacturer Uhlmann & Zacher GmbH Gutenbergstraße 2–4 97297 Waldbüttelbrunn Germany Tel.: +49 931 40672-0 E-Mail: contact@UundZ.de http://www.UundZ.de This operating and assembly manual is copyright protected. The information contained this manual should not be reproduced, distributed or used for competitive purposes or shared with third parties.
  • Page 3: Table Of Contents

    CX6162/66 ABLE OF CONTENTS Table of contents About this document ................ 3 Warnings .................... 3 Symbols ....................3 Security ..................4 Proper use ..................4 Improper use ..................4 General safety instructions ..............4 Product description ................5 Functional description ................5 Construction and scope of supply ............
  • Page 4: About This Document

    This symbols indicates a usage instruction that must be followed by the user.   This symbol indicates an entry in a list. This symbol indicates useful and important information. The name CX616x is used interchangeably for the products CX6160, CX6162 and CX6166 in this manual.
  • Page 5: Security

    CX6162/66 ECURITY Security Proper use The electronic knob cylinder CX616x is intended for installation in building doors and for locking and unlocking doors. They need to be equipped with a DIN lock for Euro profile cylinders. The CX616x locking cylinder can be used indoors as well as outdoors (depending on the product version).
  • Page 6: Product Description

    CX6162/66 RODUCT DESCRIPTION Product description Functional description The electronic knob cylinder CX616x is a Clex prime system product. The reading unit, the communication electronics, the mechanical system and power supply, are integrated within the knob module. Different transponder carriers can be used as key in the CX616x, for example, ISO card or key fob.
  • Page 7 CX6162/66 RODUCT DESCRIPTION Four-Eyes-Group The four-eyes group is used to operate a knob cylinder only when two different keys are held up, out of which one should be a member of the four eyes group and the other should have normal authorization for the knob cylinder. Which group is defined as the four-eyes group can be configured for each knob cylinder.
  • Page 8 CX6162/66 RODUCT DESCRIPTION The battery status information is sent to Keyvi and deleted from the key if the key is read by an automatic programming terminal or a programming station. A prerequisite is that the key should have been prepared for writing the information and the option Key feedback should be set in the knob cylinder.
  • Page 9 CX6162/66 RODUCT DESCRIPTION 3.1.7 Event log The last 512 events of the knob cylinder are stored in the event log. The following events are logged:  Unauthorised  Authorised  Service opening  Timer circuit open  Timer circuit closed ...
  • Page 10: Construction And Scope Of Supply

    CX6162/66 RODUCT DESCRIPTION Construction and scope of supply 3.2.1 CX6162 Grub screw Battery Mechanical knob Electronic knob Fixing screw Knob cover Cylinder casing 3.2.2 CX6166 Fixing screw Electronic knob Half cylinder casing Knob cover Battery...
  • Page 11: Variants

    CX6162/66 RODUCT DESCRIPTION Variants Different variants of the electronic knob cylinder are available for selection:  For indoor or outdoor use  Various cylinder casing lengths  Basic version without date/time and event memory...
  • Page 12: Technical Data

    CX6162/66 RODUCT DESCRIPTION Technical data 3.4.1 General technical data Name Value Dimensions of the For Europrofil locks conforming to DIN 18252 cylinder Cylinder lengths From 26/26 mm or 30/30 mm to 200/200 mm in steps CX6162 of 5 mm; Larger sizes are available upon request Cylinder lengths From 30/10 mm 200/10 mm in 5-mm steps;...
  • Page 13: Standards

    CX6162/66 RODUCT DESCRIPTION 3.4.3 Dimensions CX6162 20,0 44,3 CX6166 44,3 Standards The electronic knob cylinder CX616x meets the following standards:  EN 15684:2013 (being prepared)  EN 60529:2014 (being prepared)
  • Page 14: Management Accessories

    CX6162/66 RODUCT DESCRIPTION Management accessories The components of the Clex prime system described below are used to manage a Clex prime locking system. 3.6.1 CX6530 Keyvi management software The locking system can be managed centrally and conveniently from the PC using the Keyvi management software for Clex prime.
  • Page 15: Assembly

    CX6162/66 SSEMBLY Assembly General assembly instructions  Before assembling the CX616x knob cylinder in a fire/smoke-resistant door, please check the fire certification to ensure conformity.  Carry out the assembly necessarily with the door open.  Ensure that the latches or seals fitted to the door do not hinder the proper operation of the CX616x.
  • Page 16: Commissioning

    CX6162/66 OMMISSIONING Commissioning Initial commissioning To protect the battery from discharging during transport, the CX6162/66 is kept in transport mode till the initial commissioning. There are two options of changing over to the normal operating mode. Option 1) Turn the knob a few times to wake up the reading unit, till an LED starts ...
  • Page 17: Managing The Locking System

    CX6162/66 OMMISSIONING Managing the locking system The locking system can be managed using the Keyvi management software. Before a locking system component can be used, it has to be personalized and the settings have to be customized. 5.2.1 Personalization Every door and key in the electronic locking system Clex prime should be known to the management software for the respective locking system for subsequent programming.
  • Page 18: Operation

    CX6162/66 PERATION Operation Automatic wake up The knob cylinder is in sleep mode as long as it is not used. To check the authorization of a key, it needs to be woken up from the sleep mode. This normally happens automatically when a key is held in front of the reader unit.
  • Page 19: Opening And Locking The Door

    CX6162/66 PERATION Opening and locking the door.  Hold the authorised key in front of the reading unit till the green LED starts glowing. The knob module is now engaged and the door can be locked and unlocked  by turning the electronic knob module.
  • Page 20: Signals

    CX6162/66 PERATION Signals Function Signal (audible and visible) and explanation Rest mode No audible or visible signal ● ● Begin Service mode Two audible signals of increasing intensity but equal length ● ● End Service mode Two audible signals of decreasing intensity but equal length...
  • Page 21: Cleaning And Maintenance

    CX6162/66 LEANING AND MAINTENANCE Cleaning and maintenance Cleaning  Clean the knob cylinder only with dry or slightly damp cloth with a commercially available household cleaning agent. Do not use any abrasive or caustic cleaning agents.  Maintenance 7.2.1 Replacing the battery...
  • Page 22 CX6162/66 LEANING AND MAINTENANCE  Remove the used battery and insert the new battery, paying attention to the polarity.  Push the knob cover as far as it goes onto the knob, so that the marked spot on the knob cover aligns with the protruding plastic part on the knob.
  • Page 23 CX6162/66 LEANING AND MAINTENANCE  Insert the battery removal tool at the marking on the knob cover and push it together onto the knob as far as it goes. Remove the battery removal tool from the knob cover and check whether it is seated firmly on the knob by pulling the knob cover.
  • Page 24: Faults During Operation

    CX6162/66 AULTS DURING OPERATION Faults during operation Fault indications Function Audible signal Explanation Memory fault / 5 long beeps, ▬ ▬ ▬ ▬ ▬ ● configuration fault 1 short beep Coupling error 5 long beeps, ▬ ▬ ▬ ▬ ▬ ● ●...
  • Page 25: Disassembly And Disposal

    CX6162/66 ISASSEMBLY AND ISPOSAL Disassembly and Disposal Disassembly  Loosen the Allen screw of the mechanical knob and remove the mechanical knob from the cylinder. Remove the fixing screw.  Remove the cylinder body and electronic knob from the lock.
  • Page 26: Disposal

    CX6162/66 ISASSEMBLY AND ISPOSAL Disposal  Do not dispose of the knob cylinder with domestic waste. Disposal should be in accordance with the European Directive 2002/96/EC at a collection point for electrical waste.  Defective or used batteries should be recycled in accordance with the European Directive 2006/66/EC.
  • Page 27: Glossary

    CX6162/66 LOSSARY Glossary Definition Description ClexTouch Software for Windows handheld computer for configuring a locking system Intrusion Detection System (IDS) Keyvi Software for managing a locking system LEGIC ® Technology for contactless transfer of identification data MIFARE ® Technology for contactless transfer of identification data Data carrier that contains the authorization information.