Problem
No mains power
Battery issue (check ALARM STATUS)
No cab phone response in 24hours
Any of the expected phone lines not operational
(TEL mode)
No cab phone response in 24hours (if phone not
group 0)
All expected phone lines not operational (TEL Mode)
4.3 PLM (Phone Line Monitoring)
The Phone Line Monitoring (PLM) feature verifies the operability of the end-to-end
communications link (e.g. for elevator phone connecting to a live phone line) as required
by ASME A17.1/CSA B44 Code. Any fault detected generates an audible and visual
alert in the elevator lobby for the assigned group (elevator phones assigned to group #0
will not generate a PLM alarm). In an alarm state the communication link is re-tried
every five minutes until the failed status is cleared.
4.4 Phone LINE TEST
A phone LINE TEST feature enables on-site personnel who have access to the
consolidator keypad to go off-hook, listen for dial tone and call any number to test the
phone line operability. A similar off-site calling feature is available from any on-site
remote handset.
LED
Alarm
status
POWER
FLASHING
BATTERY
FLASHING
STATION ICON
RED
PHONE LINE
RED
PLM
RED
EMCS User Guide
Buzzer
status
Alert every 0.5 s
Alert every 0.5 s
Alert every 30 s
Alert every 0.5 s
Alert every 30 s