Engine
•
The fuel injectors are controlled by switching the ground connection.
•
The figure below shows injector voltage measutred at both connections of the injector.
1
PCM output
2
Fuel injector operation period
3
Close current
4
Hold current
Service Training Mazda6 MPS Supplement
5
Excess exciting current
6
PCM input
7
Injector driver module output
L3 Turbo
M6-MPS_01048
01-57