Cooker hood CPD - Installation and Maintenance Manual CONTENT MAINTENANCE (FOR THE USER) Cleaning ......................3 Replacing of the low energy lamp ............3 General ......................3 Operating of CPDA, CPDJ and CPDR .............4 Operating of CPDB, CPDC, CPDG, CPDH, CPDK ......5 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) Installation height ..................
Cooker hood CPD -Installation and Maintenance Manual MAINTENANCE CLEANING OF COOKER HOOD Do not use abrasive sponge or cloth. CLEANING OF GREASE FILTER Note! Do not use the cooker hood without grease filter fitted. alt. Check the grease filter every week. Clean if needed.
Cooker hood CPD - Installation and Maintenance Manual MAINTENANCE OPERATING OF CPDA, CDPJ AND CPDR Handle for boosting Lighting FläktGroup DC_8757GB_20190130_R2 Specifications are subject to alteration without notice...
Cooker hood CPD -Installation and Maintenance Manual MAINTENANCE OPERATING OF CPDB, CPDC, CPDG, CPDH AND CPDK Handle for boosting Lighting Handle for fan speed NORMAL FläktGroup DC_8757GB_20190130_R2 Specifications are subject to alteration without notice...
Cooker hood CPD - Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) INSTALLATION HEIGHT MAIN SUPPLY min 400 mm All cooker hoods has to be connected directly or indirectly via the heat recovery unit/exhaust fan to earth. If the supply cord is damaged, it must be replaced by the manufac- turer, its service agent or similarly qualified persons in order to avoid hazard.
Cooker hood CPD -Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDA Intended for multiple-unit dwellings with a central extract air fan or a heat recovery unit. Suitable for both new production and replacement of older cooker hoods. INSTALLATION BETWEEN KITCHEN CABINETS 300 mm min 500 mm...
Cooker hood CPD - Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDB Replacement hood for older exhaust air fan JBDD-aa with capacitor box, manufactured before 2007. J B D D - a J B D D - a ( e a r l i e r ( e a r l i e r v e r s i o n...
Cooker hood CPD -Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG With transformer, fits for example the new JBDH. (Fits JBDD-aa-1-2, JBFG and also as replacement cooker hood for controlling older exhaust air fans and units, for example JBDB, JBDC and RDAA.) INSTALLATION BENEATH KITCHEN CABINETS INSTALLATION BETWEEN KITCHEN CABINETS 1 7 6...
Cooker hood CPD - Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDH Replacement hood for older heat recovery units RDKG with bypass. (Fits RDKG-a-2-c-d-1). Remove the old cooker hood. Demontera den gamla spiskåpan. CPDJ For heat recovery unit RDKR or RDKS. R D K S R D K S It is important to seal the grommet by put-...
Cooker hood CPD -Installation and Maintenance Manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDK For heat recovery unit RDKG. (Fits RDKG-a-b-c-d-2). CPDR For ILOX and RDAS heat recovery units with a 5 mounting ring, or for apartment buildings with external boost damper. INSTALLATION BETWEEN KITCHEN CABINETS INSTALLATION BENEATH KITCHEN CABINETS 1 7 6...
Cooker hood CPD - Installation and Maintenance Manual ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG Note! Electrical connections have to be made by authorized personnel. EXHAUST FAN JBDB EXHAUST FAN JBDC Also for Not for conversion kit JBDC conversion kit JBDB JBDB-99-05-0 JBDB-99-05-0...
Cooker hood CPD - Installation and Maintenance Manual ADJUSTMENT CPDA, CPDB, CPDC, CPDG AND CPDR – FORCED VENTILATION When adjusting the forced air flow the fan speed must be increased up to the forced flow. b = 5 a = 25 Air flow q, l/s ∆p CPDR with basic air flow damper.
Cooker hood CPD -Installation and Maintenance Manual ADJUSTMENT CPDH AND CPDK – BASIC VENTILATION The basic air flow in the hood is adjusted by removing any number of plugs in the cover plate. 9 10 11 12 13 14 15 16 17 Air flow q, l/s 2, 4, 6, 8 och 10 = number of open holes in the cover plate.
Cooker hood CPD - Installation and Maintenance Manual ADJUSTMENT CPDH, CDPJ, CPDK AND CDPR - FORCED VENTILATION Damper blade without basic flow valve (sealed damper blade) When adjusting the forced air flow the fan speed must be increased up to the forced flow. b = 7 Air flow q, l/s ∆p...
Cooker hood CPD -Installation and Maintenance Manual SPARE PARTS CPDA, CPDB, CPDC, CPDG, CPDH, CPDJ, CPDK AND CPDR Cut the power before start working with the unit. All work has to be carried out by qualified personnel in order to avoid hazard. Passande till CPD...
Cooker hood CPD - Installation and Maintenance Manual DECLARATION OF CONFORMITY II A ENCLOSURE Declaration of Conformity In accordance with: EU Directive for Machinery, 2006/42/EC EU EMC Directive, 2014/30/EU EU RoHS Directive, 2011/65/EU Manufacturer FläktGroup Sweden AB Fläktgatan 1 551 84 Jönköping Herewith declares that: Product Type:...
Cooker hood CPD -Installation and Maintenance Manual DISPOSAL OF PRODUCT AND PACKAGING MATERIALS Recycling should be made in accordance with local regulations. When the product is scrapped the following parts/components/ materials shall be sorted. Depending on what product it is may not all parts/com- ponents/materials be represented.
Page 20
WWW.FLAKTGROUP .COM FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions.