  • Page 1 COOKER HOOD CPD TECHNICAL MANUAL FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 1 2018-04-26 16:06...
  • Page 2: Table Of Contents

    Replacing of the low energy lamp ............3 General ......................3 Operating of CPDA and CPDJ ..............4 Operating of CPDB, CPDC, CPDG, CPDH, CPDK ......5 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) Installation height ..................6 Main supply ....................6 General ......................
  • Page 3: Maintenance (For The User)

    Cooker hood CPD - Technical manual MAINTENANCE CLEANING OF COOKER HOOD Do not use abrasive sponge or cloth. CLEANING OF GREASE FILTER Note! Do not use the cooker hood without grease filter fitted. alt. Check the grease filter every week. Clean if needed.
  • Page 4: Operating Of Cpda And Cpdj

    Cooker hood CPD - Technical manual MAINTENANCE OPERATING OF CPDA AND CPDJ Handle for boosting Lighting FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 4 2018-04-26 16:06...
  • Page 5: Operating Of Cpdb, Cpdc, Cpdg, Cpdh, Cpdk

    Cooker hood CPD - Technical manual MAINTENANCE OPERATING OF CPDB, CPDC, CPDG, CPDH AND CPDK Handle for boosting Lighting Handle for fan speed NORMAL FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 5 2018-04-26 16:06...
  • Page 6: Installation (For Installers And Service Personnel)

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) INSTALLATION HEIGHT MAIN SUPPLY min 400 mm All cooker hoods has to be connected directly or indirectly via the heat recovery unit/exhaust fan to earth. If the supply cord is damaged, it must be replaced by the manu- facturer, its service agent or similarly qualified persons in order to avoid hazard.
  • Page 7: Cpda

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDA Intended for multiple-unit dwellings with a central extract air fan or a heat recovery unit. Suitable for both new production and replacement of older cooker hoods. INSTALLATION BETWEEN KITCHEN CABINETS 300 mm min 500 mm INSTALLATION BENEATH KITCHEN CABINETS...
  • Page 8: Cpdb

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDB Replacement hood for older exhaust air fan JBDD-aa with capacitor box, manufactured before 2007. J B D D - a J B D D - a ( e a r li e r...
  • Page 9: Cpdg

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG With transformer, fits for example the new JBDD and JBFG. (Fits JBDD-aa-1-2 but also as replacement cooker hood for controlling older exhaust air fans and units, for example JBDB, JBDC and RDAA.) INSTALLATION BENEATH KITCHEN CABINETS INSTALLATION BETWEEN KITCHEN CABINETS R D K S...
  • Page 10: Cpdh

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDH Replacement hood for older heat recovery units RDKG with bypass. (Fits RDKG-a-2-c-d-1). Remove the old cooker hood. CPDK For heat recovery unit RDKG. (Fits RDKG-a-b-c-d-2). FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 10 2018-04-26 16:06...
  • Page 11: Cpdj

    Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDJ For heat recovery unit RDKR or RDKS. R D K S R D K S It is important to seal the grommet by putting back the small piece of sealing material. The picture illustrates a right hand unit.
  • Page 12: Electrical Connections (For Installers And Service Personnel)

    Cooker hood CPD - Technical manual ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG Note! Electrical connections have to be made by authorized personnel. EXHAUST FAN JBDB EXHAUST FAN JBDC Not for Also for conversion kit JBDB conversion kit JBDC JBDB-99-05-0 JBDB-99-05-0 JBDA-99-031...
  • Page 13: Cpd(A, B, C, G) - Basic Ventilation

    Cooker hood CPD - Technical manual ADJUSTMENT CPDA, CPDB, CPDC AND CPDG – BASICVENTILATION 30 + 1xC 12,5 15 30 + 2xC 30 + 4xC 8 9 10 Air flow q l/s ∆p FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 13...
  • Page 14: Cpd(A, B, C, G) - Forced Ventilation

    Cooker hood CPD - Technical manual ADJUSTMENT CPDA, CPDB, CPDC AND CPDG – FORCED VENTILATION When adjusting the forced air flow the fan speed must be increased up to the forced flow. b = 5 a = 25 Air flow q, l/s ∆p...
  • Page 15: Cpd(H, K) - Basic Ventilation

    Cooker hood CPD - Technical manual ADJUSTMENT CPDH AND CPDK – BASIC VENTILATION The basic air flow in the hood is adjusted by removing any number of plugs in the cover plate. 9 10 11 12 13 14 15 16 17 Air flow q, l/s 2, 4, 6, 8 och 10 = number of open holes in the cover plate.
  • Page 16: Cpd(H, J, K,) - Forced Ventilation

    Cooker hood CPD - Technical manual ADJUSTMENT CPDH AND CPDK - FORCED VENTILATION Damper blade without basic flow valve (sealed damper blade) When adjusting the forced air flow the fan speed must be increased up to the forced flow. b = 7 Air flow q, l/s ∆p FläktGroup...
  • Page 17: Spare Parts Cpd(A, B, C, G, H, J, K)

    Cooker hood CPD - Technical manual SPARE PARTS CPDA, CPDB, CPDC, CPDG, CPDH, CPDJ AND CPDK Cut the power before start working with the unit. All work has to be carried out by qualified personnel in order to avoid hazard.
  • Page 18: Declaration Of Conformity

    Cooker hood CPD - Technical manual DECLARATION OF CONFORMITY II A ENCLOSURE  Declaration of Conformity In accordance with: EU Directive for Machinery, 2006/42/EC EU EMC Directive, 2014/30/EU EU RoHS Directive, 2011/65/EU Manufacturer FläktGroup Sweden AB Fläktgatan 1 551 84 Jönköping Herewith declares that: Product Type:...
  • Page 19: Disposal Of Product And Packaging Materials

    Cooker hood CPD - Technical manual DISPOSAL OF PRODUCT AND PACKAGING MATERIALS Recycling should be made in accord- ance with local regulations. When the product is scrapped the following parts/ components/materials shall be sorted. Depending on what product it is may not all parts/components/materials be rep- resented.
  • Page 20 WWW.FLAKTGROUP .COM FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions.