NEBMT1G8E...R3G8
Encoder cable
Instructions | Assembly
8088073
2018-05
[8088075]
Translation of the original instructions
1
Further applicable documents
All available documents for the product è www.festo.com/pk.
Observe further applicable documents:
–
Instruction manual for motor cable NEBM-T1G8...
2
Safety
2.1
Safety instructions
–
Do not connect or disconnect plug connector when powered.
–
Only assemble the product on components that are in a condition to be safely
operated.
2.2
Intended use
Connection of motor EMMS-AS to controller CMMT-AS.
3
Configuration
3.1
Product design
Fig. 1
3.2
Contact assignment
Field device side
Sock
Pin
et
RD
1
2
3
4
5
6
YE
1
2
3
4
5
6
1) Colour code in accordance with IEC 60757:1983-01
Tab. 1 Contact assignment
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
8088073
1 Socket RD, 6-pin
2 Socket YE, 6-pin
3 Plug connector RJ45
4 Cable
Wire
Signal
Pin
Controller side
1)
GY
Data+
4
PK
Data–
5
GNWH
OV
8
BNGN
Up
7
YE
Clock–
2
VT
Clock+
1
WH
OV
6
BU
UD
3
–
–
–
–
–
–
–
–
4
Mounting
4.1
Mounting, field device side
Remove cover
Fig. 2
1. Unscrew screws (C) (ß 2).
2. Remove cover (A) from connection box (B).
Ä O-rings (D) are still on the screws (C).
The O-rings (D) prevent the screws from getting lost (C) and from damaging the
main seal.
Remove the strain relief
Fig. 3
1. Unscrew screw (F) (ß 2).
2. Remove the strain relief (E).
Place the encode cable in position
Fig. 4
1. Align the encoder cable (G) so that the flat side (I) points upwards.
2. Press the sockets 1 and 2 on the correct plug connector (J).
Place the motor cable in position
Fig. 5
•
Place the motor cable (H) in the connection box è Instruction manual for
motor cable (H).