  • Page 1 26060 FB-26150 FB €•‚ƒ„…†‡ˆ‰Š‹Œ•Ž••‘’“”•–—˜™š›œ•žŸ ¡¢£¤¥¦§¨© Operating Manual State March 2010...
  • Page 2: Table Of Contents

    Hotplate 26060 FB - 26150 FB Contents Environnemental information General information Safety Technical details 6-10 Transport Commissioning Operation Cleaning Stock keeping of replacement parts and service Wiring Diagram 16-17 Appendix STATE March 2010...
  • Page 3: Environnemental Information Uw

    Hotplate 26060 FB - 26150 FB Congratulations We recommend reading these operation Please keep these operation and assembly instructions carefully in order to familiarise instructions available for possible further yourself with your new device. owners. If properly used, a good device will serve you We wish you a lot of fun using your new many years.
  • Page 4: General Information Al

    Hotplate 26060 FB - 26150 FB 4. Before connecting the device, please check if switching off the main switch or quitting the voltage of the power supply. indications on the rating plate correspond to the installation rating. 6. Don’t leave the device unnecessarily in Basic safety instructions must be observed in any case.
  • Page 5: Safety Si

    Hotplate 26060 FB - 26150 FB Safety -SI- SYMBOLS Attention Operating safety ATTENTION This note will be found everywhere in the operating manual where special This symbol will be found in all guidelines, regulations, operating safety advises in advises and the correct...
  • Page 6 Hotplate 26060 FB - 26150 FB The proper use includes observing the operating manual and conditions of inspection and maintenance. After cleaning of device check loosened connections, raw rubbed parts and damages. All detected faults have to be repaired immediately!
  • Page 7 Hotplate 26060 FB - 26150 FB Electrical connection Before connecting please observe indications on rating plate! Observe VDE-regulations and regulations of your local power supplier! Connected load 1 x 10 A Fuse protection 0,33 kW - 2 kW Voltage IN AC 230 V Special voltage upon demand Device is delivered with a helix cable of 2m length.
  • Page 8 Hotplate 26060 FB - 26150 FB Information about high temperature A T T E N T I O N ! ! ! Before putting into operation During the switching on of the device (before use) high temperatures can be reached around the heating. Please check the surface before you start working there! Don’t put paper, cardboard, cloth, etc.
  • Page 9: Technical Details Te

    Hotplate 26060 FB - 26150 FB Technical details -TE- Electrical connection: 230 V Measures total height: 115 mm Model-No.: Length mm Depth mm 26060 FB 26070 FB 26080 FB 26090 FB 26100 FB 1000 26110 FB 1100 26120 FB 1200...
  • Page 10: Electrical Connection

    Hotplate 26060 FB - 26150 FB Technical details -TE- Electrical connection: 230 V Measures total height: 115 mm Model-No.: Length mm Depth mm 26060 FB 26070 FB 26080 FB 26090 FB 26100 FB 1000 26110 FB 1100 26120 FB 1200...
  • Page 11 Hotplate 26060 FB - 26150 FB Technical details -TE- Thermostat covering with built-in cabinet Cut - out dimensions : Length minus 25 mm Depth minus 25 mm Fitting Prepare cut-out for hotplate in on-site cover plate. Also prepare cut-out for built-in cabinet of thermostat in on-site counter covering.
  • Page 12: Transport Tr

    Hotplate 26060 FB - 26150 FB Transport -TR- Packaging Transport route is important for selection of kind of packing. If not agreed upon otherwise by contract, packing corresponds to regulations of packing HPE, defined by the Federal Association for Wood Materials, Pallets, Export Packing e. V. and by the Association of German Machinery Manufacturers.
  • Page 13: Commissioning In

    Hotplate 26060 FB - 26150 FB Commissioning -IN- Before commissioning Before putting into operation of the device following items have to be checked: Shipping damages? Indications on the rating plate have to match with the local public supply system. All electrical protective measures have been carried out and serviceability has been checked.
  • Page 14: Operation Be

    Hotplate 26060 FB - 26150 FB Operation -BE- How to act in case of disturbance In addition to the following advises al local safety regulations have to be observed for the operation of the device. All electrical repairs have to be done by authorised specialists!
  • Page 15: Cleaning Re

    Hotplate 26060 FB - 26150 FB Cleaning -RE- Always make sure that device is plugged off before cleaning the hotplate. Don’t hose down the device. Only wipe device with a wet tissue using a mild cleaner if necessary. Don’t use cleaning powder.
  • Page 16: Stock Keeping Of Replacement Parts And Service Ek

    Hotplate 26060 FB - 26150 FB Stock keeping of replacement parts / after-sales service -RP- Please fill in here data of the rating plate of your device. You will find the rating plate next to the cable outlet. Gustav Scholl Apparatebau GmbH &...
  • Page 17: Wiring Diagram Sb

    Hotplate 26060 FB - 26150 FB STATE March 2010...
  • Page 18 Hotplate 26060 FB - 26150 FB STATE March 2010...
  • Page 19 Hotplate 26060 FB - 26150 FB Appendix -AN- IMPORTANT To enable our customer service to prepare repairs carefully and to provide the appropriate spare parts, please provide the following information when reporting a customer service requirement: Your precise address (where applicable, final customer's address, person to contact) 2.