  • Page 1 User Manual PON Optical Power Meter JW3213 Series Version:V2.20...
  • Page 2: Table Of Contents

    Contents Notes ---------------------------------------------------- 2 1.Standard Configuration --------------------------------- 1 2.Overview ----------------------------------------------- 3 3.Technical Specifications -------------------------------- 6 4.Instruction -------------------------------------------- 7 5.Trouble shooting -------------------------------------- 21 6.Maitanance -------------------------------------------- 22 7.Warranty & Servicing ---------------------------------- 22 Appendix I ---------------------------------------------- 24...
  • Page 3: Notes

    Notes Icon Meaning: In this manual will appear some text with the below icon,The meaning as follows: Warning:Improper behavior and operation, to prevent any wrongdoing and harm. Note: Due to the improper operation may cause harm to the human body or product, so special note to warn the user.Please make sure that! Important note:...
  • Page 4: Standard Configuration

    1.5VAA Battery Chapter 2 Overview JW3213 Series PON Optical Power Meter target at the FTTx application and maintenance. This power meter is able to simultaneously test and estimate the signals of the voice, data and video. It is an essential and ideal tool for the construction and maintenance of the PON projects.
  • Page 5: Technical Specifications

    ⑸.USB communication port enables data transfer to a PC.1000measurement items can be saved in JW3213 PON power meter or computer for data review. ⑹ . With optical power meter module,include850 、 1300 、 1310 、 1490 、 1550 、 1625sixs(JW3213AP , JW3213Awithout850nmwavelength ) ; With visual fault locator module (JW3213andJW3213AV)...
  • Page 6 MeasurementRange(dBm -40dBm~+20dBm Input power(max) 25dBm Isolation@ >40dB (1310/1490nm) Measurement Accuracy Connatural ±0.5dB uncertainty(dB) Linearity(dB) ±0.1dB Passing through insertion <1.5dB Loss(dB) General Information Detector Type InGaAs Optical Connector FC/SC/ST Interchangeable/2.5 universal adapter Fiber Type SM 9/125um Measurement Unit dB/dBm/xW Resolution (dB) 0.01dB DC 3.3V~5.5V Operation Voltage(V)
  • Page 7 Connatural ±0.5dB uncertainty(dB) Linearity(dB) None ±0.1dB Measurement -70dBm~+6dBm Range(dBm) General Information Measurement Unit dB/dBm Resolution (dB) 0.01dB None Calibration 1300/1310/ 850/1300/1310/ Wavelength(nm) 1490/1550/1625 1490/1550/1625 Detector Type InGaAs Optical Connector FC/SC/ST Interchangeable/2.5 universal adapter ②:JW3213do not have the OPM module VFL Module: ③...
  • Page 8: Instruction

    Chapter 4 Instruction JW3213 / JW3213A two models are different between functions and the form, detailed in this chapter, please check carefully. 1.Describtion 1- OLT/VIDEO:1490nm/1550nm Down Stream 2- ONT:1310nmUp Stream Port(1310nm) 3- VFL or OPM Port 4- Display 5- ONT1310nmUp Stream Port LEDs 6- OLT1490nm/1550nm Down Stream LEDs...
  • Page 9 7- Video signal LEDs (1550nm) 8- AUTOpower/off key 9-UPIn the first interface, switch visual fault location model(VFL) 10- ENTER: Confirmation the function selection and saving the data. 11- MENU: PON/CW Power meter module Option 12- DOWM,In the first interface,Switch betweenVFL in continuous light (the CW) and pulse light (HZ) 13- CANCEL:Function cancel 14- USB PORT...
  • Page 10: Data Communication

    Variable Optical Attenuator Data Networks Analyser Optical Splitter IXIA/Smartbits …… 1490nm Fiber 1310nm Lamda Multiplexer The sensitivity test configuration diagram Data Communication Run the CD,install USB driver software CP210x_VCP_Win2K_XP_S2K3.exe. Then install dotNetFx40_Full_x86_x64.exe. Connect JW3213 PON power meter to the computer’s port using the provided USB cable,Open the software as shown in below figure: Upload the data...
  • Page 11 (1)Open the JW3213PON power meter,first of all click “connect”,connect JW3213PON power meter to the computer(Click“English”to set the language of the operation interface to be English ) (2) choose “Upload Data”, click “Upload Test Data”sign, the saved data can be read on the computer, and saved as a file format. (3)click the“Delete Test Data”...
  • Page 12 From the toolbar, select “Threshold Set”, and right click the Threshold to type or modify the threshold value. Calibration Choose “Calibration” tab, the user can perform user self-calibration operation also can choose “Factory Reset” mode. For example, the current optical power at 1310nm is -10dBm, type -10dBm in the text box of input standard power, and click Calibration tab, then finished the calibration operation at 1310nm wavelength.
  • Page 13 As shown in above figure, the LCD will display simultaneously three wavelengths of 1310nm upstream measurement and 1490nm,1550nm downstream measurements. When optical signal is present under test, the optical channel will display power levels in dBm, when optical signal is not available, then the optical channel will display “LOW”. “ ”indicates 10 minutes auto-off function is activated.The unit will turn itself off after 10 minutes of idle time.
  • Page 14 “ ” to choose the required threshold value,(The thresholds rang and name have already set in the software, and also download to the instrument, please check with the user manual of Chapter 6 data communication), For example choose threshold and name it as “a” and press“...
  • Page 15 will be break, and the tested value will be faulty if the un-matched adaptor connected Pay attention to the type of the measured optical fiber connectors, does not match the type of access instrument, may damage the instrument output optical fiber connector,and can not get the true result.
  • Page 16 ”, there will displaying saving on the screen, check with the Press“ upper pic. The data recording series No.is 0002. press“ ” saving, and “ ” for cancel, and the saving recording can be checked in the “data view” under “historical data” Menu. After finish the testing work, keep the connect port clean, so cover the dusty-cap once finish the work.
  • Page 17 display relative value (dB), see as following: In order to get the loss between the two measurements, do another time testing under the first relative output power. The relative value will be calculated automatically. For example the second time testing of 1310nm output power is -35dBm, the relative output power will be -15dBm.(relative output power=absolute output power-reference value -15dBm=-35.00dBm- (-20.00dBm)...
  • Page 18 again to close this function ⑥:JW3213&JW3213AP without this function. Other function instruction: PON Power Meter: Relative output power measurement: As per requirements of measurement to select the different wavelengths and Ref settings, relative power=testing value-Ref value. Press to select the different wavelengths, Press“ ”...
  • Page 19 to select the corresponding shresholds. With using JW3213.exe software to modify the values range and names of thresholds (Detailsas explained in term 5-Data Communication.) Status LEDs-JW3213 ⑦:Threshold Selection just can be use English or figure,can not use Chinese. Switches of measurements units Measure the output power of the fiber use dBm or Xw, Press “...
  • Page 20 and cancel the current operation. Time setting In item 5 have “ Time Setting”Press select the “Time Set”option, and press to change year-month-date-time respectively as shown in below figure,use to change the digits. After setting, press “ ” to confirm.Press “ ”...
  • Page 21 ⑴ .”Data View” Under “History data”, use to highlight “Data View”, press “ ” to confirm and view the history data as shown in below figure. Press “ ” to exit. As shown in above figure, when there is no optical signal to be tested, the power level will show -40dBm at 1310nm&1550nm and -50dBm at 1550nm, when the optical signal is present, the unit will display the corresponding tested value.
  • Page 22: Troubleshooting

    . “Del All” ⑶ Under “History data”, use to highlight “Del All”, press “ ” to confirm to delete all the saved history data as shown in below figure. Chapter 5 Troubleshooting Problem Possible Cause Solution No display on 1. Power Off ”...
  • Page 23: Warranty & Servicing

    Joinwit promises to repair or replace free of charge. But the freight cost and related taxes will be shared by both parties. Joinwit will pay the shipping cost from customer side to Joinwit and pay the import taxes in China.
  • Page 24 ⚫ Failures and damages occurred because of failing to comply with the Operation Instruction and necessary attention. ⚫ abnormal conditions of operation or handling: Such as artificial damage, or operating in abnormal conditions of like high temperature、 high voltage, humidity and etc., Joinwit will charge depend on the actual failure rating.
  • Page 25: Appendix I

    Appendix I An important message from JOINWIT JOINWIT guarantees that any information you supply will remain confidential. By returning this card, you will automatically be notified about updates, modifications, and recalibration. CUSTOMER SERVICE Phone: 86-21-51591648 Fax: 86-21-51591519 joinwit@joinwit.com www.joinwit.com -----------------------------------------------------------------------------------------------------...